H | 67 |
Heater Assembly
23
1 4
5
6
7
Fig. | Fig. |
The Heater Assembly, Fig.
HEATER ASSEMBLY REMOVAL:
See Fig.
Now, release the Heater Assembly Locking Tab, item 2, and while holding the tab open bring the Heater Assembly up on the left side, disengaging the heaters two discharge outlets from the Sump, item 3, and then out from the Circulation Pump Connection, item 4.
Heater Assembly Components, Fig.
1. | Intake from Circulation Pump. | 5. | Locking Tab |
2. | Discharge to Lower Spray Arm. | 6. | NTC Socket |
3. | Discharge to Upper Spray Arm. | 7. | Flow Switch |
4.Aqua Sensor (if equipped).
TO INSTALL:
Slide the Heater Assembly into the Circulation Pump Connection first, then bring the Heater down and seat the two outlet gaskets back into the Sump. Make sure all three gaskets are secure and the locking tab is in place. Then replace the two screws and wiring connections.
Top Rack Actuator, Fig.
Top Rack Actuator is used to activate the Top Rack Only wash on models equipped with this feature. When activated, the Top Rack Actuator diverts all water flow to the Upper Spray Arm.
To remove the Actuator, remove the wire connector, and then pry the Actuator out from its housing. When installing, make sure the Actuator’s arm is properly inserted back into the Control Gate.