48

H

Water Inlet / Discharge System – Removal

1

Fig. 12-7

Fig. 12-8

The Water Level Switch and Diaphragm are replace as one assembly. To replace, bend the small retaining tab out away from the assembly.

Fig. 12-9

To replace either Drain Hose, first remove the Drain Hose retaining clip.

Then remove the wiring connector and slide the assembly up and out from the Water Level Housing.

The Float Switch, item 1, is a press fit and easily removed as an individual component.

Fig. 12-10

Then bring the hose down and out from the Water Chamber. When re-installing make sure the hose is snug, and the retaining clip is back in place.

Page 50
Image 50
Bosch Appliances 6805, TRUE, 6806, 4306, 4302, 6802 manual Water Inlet / Discharge System Removal