Trouble shooting guide

 

 

 

 

 

 

 

CONDITION/Problem

THINGS TO CHECK

 

SOLUTION

 

 

 

 

 

 

 

1-

Unit will not power up/

Outlet

 

Make sure outlet is functioning correctly. Verify this by

 

 

turn on/start

 

 

plugging another object (ex: lamp) into the outlet. If outlet

 

 

 

 

 

is connected to a light switch, check to make sure it is on.

 

 

 

 

 

If outlet is not functioning find a working outlet.

 

 

 

Power cord not plugged

 

Make sure the power cord is firmly secured to A/C inlet on

 

 

 

in.

 

the front of the unit and firmly inserted into a non-GFI wall

 

 

 

 

 

socket.

 

 

 

Power switch turned off.

 

Make sure the power switch at the rear of the unit is in the

 

 

 

 

 

“ON” position.

 

 

 

Safety key not plugged in.

 

Plug Safety Key into magnetic safety key location on

 

 

 

 

 

display. (See Emergency Stop Procedure within the

 

 

 

 

 

Important Safety Precautions section)

 

 

 

Safety key magnet not

 

Try another magnet if available, such as refrigerator

 

 

 

functioning.

 

magnet. If unit works with different magnet replace

 

 

 

 

 

safety key.

 

 

 

LED Diagnostic needed.

 

Access diagnostic LEDs on motor controller board by

 

 

 

 

 

following the instructions in the TC5300/6000 Diagnostics.

 

 

 

 

 

Caution: Machine is on. Current is active!!.

 

 

 

 

 

Check the B & G LEDs for the following:

 

 

 

 

 

If neither B nor G are lit power is not reaching the motor

 

 

 

 

 

controller. Disconnect unit from power source and check

 

 

 

 

 

wiring integrity and connections between A/C inlet

 

 

 

 

 

(where cord plugs in to machine) and motor controller

 

 

 

 

 

board. If any visible damage replace A/C junction kit. If

 

 

 

 

 

light G is lit but light B is not lit replace motor controller

 

 

 

I/O Cables

 

If LEDs B & G are both lit check connections and for signs

 

 

 

 

 

of visible damage to any of the three I/O calbes. If no

 

 

 

 

 

visible damage check continuity using a multi-meter. If a

 

 

 

 

 

multi-meter is not available replace all three cables.

 

 

 

Console control board

 

If I/O cables are all functioning properly, LEDs B & G are

 

 

 

 

 

lit up, and machine still will not power up replace upper

 

 

 

 

 

console control board

 

2

Speed displayed is not

Display set to wrong

 

Change display units. (See Console Display & Set Up

 

 

accurate.

unit of measure.

 

section)

 

 

 

(English/Metric)

 

 

 

 

 

Out of calibration.

 

Re-calibrate machine. (See Calibration Procedures Pg. 26)

 

 

 

 

 

 

 

3

Heart rate not displayed

Transmitter not making

 

Moisten skin contact area on the chest strap. (See Heart

 

 

while using chest strap.

good contact with skin.

 

Rate Monitoring Pg. 23)

 

 

 

Electromagnetic

 

Turn off any television, AM radio, microwave, or computer

 

 

 

interference.

 

within 6 feet (2 meters) of theTreadClimber® fitness

 

 

 

 

 

machine.

 

 

 

Chest strap transmitter.

 

Test chest strap with another HR monitoring device such

 

 

 

 

 

as HR watch, machine at a gym. If transmitter has good

 

 

 

 

 

skin contact and still is not found to be emitting HR signal

 

 

 

 

 

replace chest strap transmitter.

 

 

 

 