134Routine Maintenance

Replace the Fuse (360X-Plus II Only)

Replace the Fuse (360X-Plus II Only)

The instructions that follow are for the 360X-Plus II series printers only. The 300X-Plus II and 600X-Plus II fuses are not user-replaceable.

Caution • Turn the AC power switch off (O) and remove the power cord before performing this procedure.

The printer uses a metric-style fuse (5 × 20 mm IEC) rated at F5A, 250 V. The AC power entry module comes with two approved fuses in the fuse holder: one is in-circuit, and the second is provided as a spare. The end caps of the fuse must bear the certification mark of a known international safety organization (see Figure 11 on page 25).

To replace a faulty fuse, complete these steps:1.Use a small-blade screwdriver or similar tool to remove the fuse holder.

The fuse holder is part of the AC power entry module at the rear of the printer (Figure 36).

Figure 36 • AC Power Entry Module

1

2

3

4

1Power switch

2Fuse holder3AC power entry module4Small-blade screwdriver

2.Remove the faulty fuse and install a new fuse in the in-circuit position (Figure 37). Important • If you use the spare fuse, be sure to order a replacement fuse from an

authorized Brady distributor. The spare fuse should be the exact type and rating as the original in-circuit fuse.

14068L-001 Rev. A

X-Plus II User Guide

1/11/07