Operations 51

Adjust Media Sensors

5.Tighten the adjustment screw to secure the upper media sensor.

Upper Media Sensor—Outside Half of Media

To adjust the upper media sensor for the outside half of the media, complete these steps:

1.Remove the ribbon (if ribbon is used).

2.See Figure 20. Locate the upper media sensor. The upper media sensor eye is directly below the adjustment screw head.

3.Using a Phillips-head screwdriver, remove the upper media sensor adjustment screw.

4.Lift the upper media sensor assembly from the slot, and move it and the wire cover to the outside slot. Carefully pull the wires through the cable tie. You may need to set aside the sensor wire cover if the adjustment is too far to the outside.

5.Replace and slightly tighten the adjustment screw.

6.Slide the upper media sensor along the slot to the desired position (for non-continuous media with a notch or hole in the media, the sensor must be directly above the notch or hole).

7.Tighten the adjustment screw.

8.Make sure that the wires are routed back into the groove of the media sensor bracket.

1/11/07

X-Plus II User Guide

14068L-001 Rev. A