Brocade Communications Systems 53-1002580-01 manual Connecting to the Alarm Port

Models: 53-1002580-01

1 82
Download 82 pages 47.33 Kb
Page 34
Image 34

2 Connecting to the Alarm Port

Connecting to the Alarm Port

The DB-15 alarm port on the switch’s front panel is used to provide alarm. The switch supports two sets of alarm relay contacts (major and minor), and 4 external customer site alarm inputs. The pin assignments used to connect to the alarm port are provided in the following table.

FIGURE 19 ALARM PORT (D-15) PIN OUT

1

15

Wiring Map for Alarm Cable

The signals include relay contacts for major and minor system alarms, and external alarm inputs.

TABLE 4

SYSTEM STATUS LEDs

 

 

 

Switch’s Alarm Port

Funtion

 

 

 

1

(MJR_ALARM_CNTR)

Common contact for major alarm relay.

 

 

 

2

(MNR_ALARM_CNTR)

Common contact for minor alarm relay.

 

 

 

3

(ALARM_IN3_EXT_P*)

External alarm input 3 (external relay dry contact closure to pin 13).

 

 

 

4

(ALARM_IN4_EXT_P)

External alarm input 4 (external relay dry contact closure to pin 8).

 

 

 

5

(No Contact)

 

 

 

 

6

(MJR_ALARM_NO)

Normally open during major alarm state.

 

 

 

7

(MNR_ALARM_NO)

Normally open during minor alarm state.

 

 

 

8

(ALARM_IN4_EXT_RTN†)

External alarm input 4 (external relay dry contact closure from pin 3).

 

 

 

9

(ALARM_IN1_EXT_P)

External alarm input 1 (external relay dry contact closure to pin14).

 

 

10 (ALARM_IN2_EXT_P)

External alarm input 2 (external relay dry contact closure to pin 15).

 

 

11 (MJR_ALARM_NC)

Normally closed during major alarm state.

 

 

12 (MNR_ALARM_NC)

Normally closed during minor alarm state.

 

 

13 (ALARM_IN3_EXT_RTN)

External alarm input 3 (external relay dry contact closure from pin 3).

 

 

14 (ALARM_IN1_EXT_RTN)

External alarm input 1 (external relay dry contact closure from pin 9).

 

 

15 (ALARM_IN2_EXT_RTN)

External alarm input 2 (external relay dry contact closure from pin 10).

 

 

 

 

* P indicates positive input.

† RTN indicates return to Ground.

20

Brocade 6910 Ethernet Access Switch Hardware Installation Guide

 

53-1002580-01

Page 34
Image 34
Brocade Communications Systems 53-1002580-01 manual Connecting to the Alarm Port, Wiring Map for Alarm Cable