Brocade 6910 Ethernet Access Switch Hardware Installation Guide 27
53-1002580-01
Appendix
BCables

Twisted-Pair Cable and Pin Assignments

For 10/100BASE-TX connections, the twisted-pair cable must have two pairs of wires. For
1000BASE-T connections the twisted-pair cable must have four pairs of wires. Each wire pair is
identified by two different colors. For example, one wire might be green and the other, green with
white stripes. Also, an RJ-45 connector must be attached to both ends of the cable.
CAUTION
DO NOT plug a phone jack connector into any RJ-45 port. Use only twisted-pair cables with RJ-45
connectors that conform with FCC standards.
CAUTION
Caution: Each wire pair must be attached to the RJ-45 connectors in a specific orientation.
The figure below illustrates how the pins on the RJ-45 connector are numbered. Be sure to hold the
connectors in the same orientation when attaching the wires to the pins.
FIGURE 22 RJ-45 CONNECTOR PIN NUMBERS

10BASE-T/100BASE-TX Pin Assignments

Use unshielded twisted-pair (UTP) or shielded twisted-pair (STP) cable for RJ-45 connections:
100-ohm Category 3 or better cable for 10 Mbps connections, or 100-ohm Category 5 or better
cable for 100 Mbps connections. Also be sure that the length of any twisted-pair connection does
not exceed 100 meters (328 feet).
The RJ-45 ports on the switch base unit support automatic MDI/MDI-X operation, so you can use
straight-through cables for all network connections to PCs or servers, or to other switches or hubs.
In straight-through cable, pins 1, 2, 3, and 6, at one end of the cable, are connected straight
through to pins 1, 2, 3, and 6 at the other end of the cable. When using any RJ-45 port on this
switch, you can use either straight-through or crossover cable.