3. INSTALLATION
<Main P. C. board >
Lock the cord clamp securely.
<Removal>
Press the tab.
<Securing>
2289B
Connectors | Connection location on | Cord clamps | ||
main P. C. board | ||||
|
| |||
X pulse motor encoder | P17 | (2) | ||
Y pulse motor encoder | P18 | (2) | ||
Work clamp pulse motor encoder | P19 | (2) | ||
Thread nipper pulse motor encoder | P20 | (2) | ||
Machine head switch | P14 | (2) | ||
Machine head memory | P16 | (2) | ||
Thread trimmer solenoid | P2 (SOL1) | (1) | ||
Digital tension | P3 (SOL2) | (1) | ||
Thread clamp pulse motor | P4 (TPM) | (1) | ||
X pulse motor | P21 | (XPM) | (1) | |
Y pulse motor | P22 | (YPM) | (1) | |
Work clamp pulse motor | P23 | (PPM) | (1) |
NOTE: Route the X, Y and work clamp pulse motor harnesses so that they do not touch the power supply P.C. board.