10. TABLE OF ERROR CODES
Communication and
Code | Cause and remedy | |
| Communication error detected between the main P.C. board and the panel P.C. board when the power was | |
E400 | turned on. | |
Turn off the power, and then check that connector P1 on the panel P.C. board and connector P3 on the motor | ||
| ||
| P.C. board are properly connected. | |
| Communication error detected between the main P.C. board and the motor P.C. board when the power was | |
E401 | turned on. | |
Turn off the power, and then check that connector P5 on the main P.C. board and connector P2 on the motor P.C. | ||
| ||
| board are properly connected. | |
E410 | Communication error between main P.C. board and panel P.C. board detected. | |
Turn off the power, and then turn it back on again. | ||
| ||
E411 | Communication error between main P.C. board and motor P.C. board detected. | |
Turn off the power, and then turn it back on again. | ||
| ||
E420 | No media is inserted. | |
Press the RESET key to clear the error. | ||
| ||
| Data contents are incorrect and cannot be used, or no data. | |
E421 | Press the RESET key to clear the error. | |
| Check that data for this pattern number is present in the media. | |
E422 | Error occurred while reading from media. | |
Press the RESET key to clear the error. | ||
| Check the data in the media. | |
E424 | Insufficient space in media. | |
Press the RESET key to clear the error. | ||
| Use different media. | |
| Error occurred while reading from media. | |
E425 | Press the RESET key to clear the error. | |
Use the specified type of media. | ||
| ||
| Check if the media is | |
| A pattern registered in a cycle program has been erased. | |
E427 | Press the RESET key to clear the error. | |
| ||
E428 | A pattern registered in a program has been erased. | |
Press the RESET key to clear the error. | ||
| ||
E430 | Data cannot be backed up to main P.C. board. | |
Turn off the power, and then turn it back on again. | ||
| ||
E440 | Data memory error on main P.C. board. | |
Turn off the power, and then turn it back on again. | ||
| ||
E450 | Model selection has not been loaded from the machine head memory. | |
Turn off the power and check that connector P16 on the power supply motor P.C. board is properly connected. | ||
| ||
E451 | Data cannot be backed up to machine head memory. | |
Turn off the power, and then turn it back on again. | ||
| ||
E452 | Machine head memory is not connected. | |
Turn off the power, and then check that connector P16 on the main P.C. board is properly connected. | ||
| ||
| Internal memory is full and copying is not possible. | |
E474 | Press the RESET key to clear the error. | |
| Clear any unnecessary additional patterns. |
74 |