6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)6-1. Setting memory switches
1 | Change the mode to memory switch setting mode. | While pressing the TEST key, press the TENSION key. | |||||
| All indicators switch off |
|
|
|
|
|
|
|
| The memory switch number will be displayed in the | |||||
|
| PROGRAM No. display and the setting value for that | |||||
|
| number will be displayed in the menu display. |
| ||||
| Menu indicator switches off, TEST indicator flashes |
|
|
|
| 2420B | 2421BB |
|
|
|
|
|
|
| |
2 | Select the memory switch that you would like to change | Press the | or |
| key to | select the memory | switch |
| the setting for. | number. |
|
|
|
|
|
|
|
|
|
|
|
| 2422B |
| If you would like to display only the numbers of | While pressing the SELECT key, press the or | key | ||||
| memory switches that have been changed from default | (1). |
|
|
|
|
|
| settings | The numbers of memory switches that have been | |||||
|
| changed from default settings will appear in order. |
| ||||
|
|
|
|
|
|
| 2423B |
|
|
|
|
|
| ||
3 | Change the memory switch parameters. | Press the | or | key to change the setting value. |
| ||
|
| The flashing display means that the setting has not yet been | |||||
|
| applied. |
|
|
|
|
|
|
| You can make the initial setting appear in the display by | |||||
|
| pressing the RESET key. |
| 2424B | |||
4 | Apply the changed parameter setting. | Press the ENTER key. |
|
|
| ||
|
| The menu display will change from flashing to | |||||
|
| illuminated, and this means that the parameter setting | |||||
|
| has been applied. |
|
|
| ||
|
| If you | press | the | or | key (1) or the TEST key | |
| 2414B | without pressing the ENTER key, you can cancel the | |||||
| parameter changes. |
|
| ||||
5 | Repeat steps 2 to 4 above to set each memory switch. |
|
|
|
|
|
|
|
|
|
|
|
| ||
6 | Exit setting mode. | Press the TEST key. |
|
|
| ||
|
| The changes will be memorized and the sewing | |||||
|
| machine will switch to home position detection standby. | |||||
| TEST indicator switches off |
|
|
|
|
| 2404B |
44 |