| 6. USING THE OPERATION PANEL (ADVANCED OPERATIONS) | |
|
|
|
|
|
|
|
|
| |
| <Setting the counter value> |
|
| |
| 1 | Change the mode to production counter setting | While pressing the TEST key, press the key. |
|
|
| mode. |
|
|
|
|
| The 7 digits of the current counter value will be |
|
|
|
| displayed in the PROGRAM No. display and the |
|
|
|
| menu display. |
|
|
| SPEED indicator illuminates |
|
|
|
| TEST indicator and COUNTER indicator illuminate | 2429B 2430B |
|
| 2 | Change the counter value. | Press the or key (1) to set the counter value. |
|
|
|
| • The counter value can be set from [000][0000] to |
|
|
|
| [999][9999]. |
|
|
|
| • If you press the RESET key during setting mode, the |
|
|
|
| value will become [000][0000]. |
|
|
|
| • If the value is changed, the display will change to |
|
|
|
| flashing. |
|
|
| For example, |
|
|
|
| 1,234,500. |
|
|
|
|
| 2431B |
|
|
|
|
|
|
| 3 | Apply the changed parameter setting. | Press the ENTER key. |
|
|
|
| The value will be applied and the display will change |
|
|
|
| to illuminated. |
|
|
| 2414B | If you press the TEST key without pressing the |
|
|
| ENTER key, you can cancel the parameter changes. |
| |
| 4 | Ending setting mode | Press the TEST key. |
|
|
| TEST indicator switches off | 2404B |
|
The production counter is always operating. (It operates even if the production counter display is not active.) If you press the SELECT key so that the COUNTER indicator illuminates when memory switch No. 300 is ‘ON’, the current production counter value will be displayed in the menu display instead of the lower thread counter value. (The SPEED indicator will also illuminate at this time.)
1. The counter is incremented by 1 each time one sewing operation is complete. If the production counter display is active, the number being displayed in the menu display (1) will be incremented by 1.
* If you would like the digits to be displayed in all columns, use the temporary display function described below.
* If you press the RESET key (2) for 2 seconds or more, the counter value can be reset to [0000].
Temporary display function
While pressing the ENTER key, press the F1 key. The production counter will be displayed as 7 digits while the keys are being pressed.
While pressing the ENTER key, press the F2 key. The lower thread counter will be displayed while the keys are being pressed.
2432B