5. USING THE OPERATION PANEL (BASIC OPERATIONS)

4

Select the item to be changed.

Press the SELECT key.

 

 

 

 

 

 

2401B

 

 

 

￿The selected parameter changes in the order shown in

 

 

 

the illustration below each time the SELECT key is

 

 

 

pressed.

 

 

 

Pattern ￿ X-scale ￿ Y-scale ￿ Sewing speed ￿ Slow start pattern￿ Upper thread tension

 

 

 

 

 

5

Change the setting for the parameter.

 

 

 

 

(Refer to “List of parameters” on the next page for details

Press the

or

key to change the parameter

 

on parameter changes. ￿

 

setting.

 

 

 

 

 

 

 

 

 

 

 

 

2382B 2383B

 

 

 

￿The flashing display means that the parameter setting

 

 

 

has not yet been applied.

 

 

 

￿You can make the initial setting appear in the display

 

 

 

by pressing the RESET key.

 

 

2402B

 

 

 

 

 

 

 

6

Apply the changed parameter setting.

Press the ENTER key.

 

 

 

 

￿The display will change from flashing to illuminated,

 

 

 

and this means that the setting has been applied.

 

 

 

￿If you press the SELECT key or the TEST key without

 

 

 

pressing the ENTER key, you can cancel the

 

 

 

parameter changes.

 

 

 

2403B

 

 

 

 

 

 

 

7

Repeat steps 4 to 6 above to record the settings for each parameter.

 

 

 

 

8

If you would like to continue setting another program, repeat steps 2 to 7 above.

 

 

 

 

 

9

Exit program mode.

 

Press the TEST key.

 

 

2404B

TEST indicator switches off

￿The display will return to the normal display.

 

 

 

 