10.TABLE OF ERROR CODES
Upper shaft
Code | Cause and remedy | |
| Sewing machine has continued to be used for a certain period after the “GREASEUP” notification appears | |
E100 | without the grease being applied (without the reset procedure being carried out). | |
| Apply grease and then carry out the reset procedure. (Refer to the service manual for the reset procedure.) | |
E111 | Upper shaft did not stop at the needle up stop position when the sewing machine stopped. | |
Turn off the power, and then check that there are no problems with the thread trimming mechanism and the | ||
| machine motor mechanism. | |
E121 | Thread trimming was not completed. | |
Turn off the power, and then check if the cutting edges of the fixed knife and movable knife are damaged or worn. | ||
| ||
| Sewing machine motor stopped due to a problem, or synchronizer is faulty. | |
E130 | Turn off the power, and then turn the machine pulley to check if the machine has locked up. | |
Check that connector P11 on the power supply motor P.C. board and the | ||
| ||
| properly connected. | |
E131 | Synchronizer is not connected correctly. | |
Turn off the power, and then check that connector P11 on the power supply motor P.C. board is properly | ||
| connected. | |
E132 | Problem detected with sewing machine motor operation. | |
Turn off the power, and then check that connector P11 on the motor P.C. board is properly connected. | ||
| ||
E133 | Sewing machine motor stopping position is incorrect. | |
Turn off the power, and then check that connector P11 on the motor P.C. board is properly connected. | ||
| ||
| Sewing machine motor is overheating, or temperature sensor is faulty. | |
E150 | Turn off the power, and then check the sewing machine motor. | |
(When sewing data with a small number of stitches (15 stitches or less) is sewn repeatedly (short cycle | ||
| ||
| operation), the upper shaft motor may overheat and the “E150” error code may be generated.) | |
Feed | ||
Code | Cause and remedy | |
E200 | X feed motor home position cannot be detected. Problem with X feed motor or poor X encoder connection. | |
Turn off the power, and then check that connectors P17 and P21 on the main P.C. board are properly connected. | ||
| ||
E201 | X feed motor stopped abnormally. | |
Turn off the power and check that there is no problem with the X feed direction. | ||
| ||
E204 | X feed motor stopped abnormally during sewing. | |
Turn off the power and check that there is no problem with the X feed direction. | ||
| ||
E205 | ||
Turn off the power and check that there is no problem with the X feed direction. | ||
| ||
E206 | X feed motor stopped abnormally during test feeding. | |
Turn off the power and check that there is no problem with the X feed direction. | ||
| ||
E210 | Y feed motor home position cannot be detected. Problem with Y feed motor or poor Y encoder connection. | |
Turn off the power, and then check that connectors P18 and P22 on the main P.C. board are properly connected. | ||
| ||
E211 | Y feed motor stopped abnormally. | |
Turn off the power and check that there is no problem with the Y feed direction. | ||
| ||
E214 | Y feed motor stopped abnormally during sewing. | |
Turn off the power and check that there is no problem with the Y feed direction. | ||
| ||
E215 | ||
Turn off the power and check that there is no problem with the Y feed direction. | ||
| ||
E216 | Y feed motor stopped abnormally during test feeding. | |
Turn off the power and check that there is no problem with the Y feed direction. | ||
| ||
Work | ||
Code | Cause and remedy | |
E300 | Work clamp home position cannot be detected. Problem with work clamp motor or poor work clamp encoder | |
connection. | ||
| Turn off the power, and then check that connectors P19 and P23 on the main P.C. board are properly connected. | |
E301 | Work clamp/button clamp raised or lowered position cannot be detected. | |
Turn off the power, and then check that there is no problem with the vertical work clamp/button clamp position. | ||
|
73 |