2. INSTALLATION
0481D 5. Knee lifter plate
<Knee lifter adjustment>
1. Turn the machine pulley so that the feed dog is below the top of the needle plate.
2. Lower the presser foot (1) by using the lifting lever (2).
3. Loosen the nut (3).
4. Turn the screw (5) to adjust so that the amount of play in the knee lifter is approximately 2 mm when the knee lifter plate (4) is gently pressed.
5. Securely tighten the nut (3).
6. Loosen the nut (6).
7. Turn the adjusting screw (8) to adjust so that the presser foot (7) is at the desired position within a distance of 13 mm of the needle plate when the knee liter plate is fully pressed.
8. After adjustment is completed, securely tighten the nut
(6).
Within 13 mm
0482D
5 |