| 8. TROUBLESHOOTING | ||
|
|
|
|
| |
|
|
|
|
| |
| Error code | Possible cause | Page |
| |
| E150 | ・ This is displayed when the motor becomes abnormally hot and the temperature |
|
| |
| protection has activated. |
|
| ||
| Motor is |
| After the temperature has dropped, turn on the power switch and operate the |
|
|
| overheating. | sewing machine as normal. |
|
| |
|
|
|
|
|
|
| E151 | ・ The connection of the |
|
| |
| Turn off the power switch, and then check the connection of the |
|
| ||
| Problem with | connector. |
|
| |
| motor |
| ・ Problem with motor or main PCB. |
|
|
| overheating | Replace the motor or the control box. | ** |
| |
| sensor. |
|
|
| |
|
|
|
|
|
|
| E161 | ・ This is displayed when a motor overload operation has occurred. |
|
| |
| Turn off the power switch, and then turn the pulley by hand and check that it |
|
| ||
| Motor | overload | turns easily. |
|
|
| protection | ・ Problem with motor. |
|
| |
|
|
| Replace the motor. |
|
|
|
|
|
|
|
|
| E190 | ・ This appears on the display when the sewing machine has been operating |
|
| |
| continuously for 3 minutes or more. |
|
| ||
| Motor timeout. | Turn the power switch off and then back on again, and then operate the sewing |
|
| |
|
|
| machine normally. |
|
|
|
|
|
|
|
|
| E191 | ・ This is displayed if the sewing machine motor locks during thread trimming. |
|
| |
| Remove any thread scraps that may be blocking the motor. | * |
| ||
| Thread | trimming | Check that there are no problems with the thread trimming mechanism. | ** |
|
| solenoid timeout. |
|
|
| |
|
|
|
|
|
|
| E410 | ・ Is the |
|
| |
| Turn off the power switch, and then check the connection of the |
|
| ||
| Error |
| panel connector. | 7* |
|
| communicating |
|
|
| |
| with operation |
|
|
| |
| panel. |
|
|
|
|
| E440 | ・ Problem with main PCB. |
|
| |
| Replace the control box. | ** |
| ||
| Error writing data |
|
| ||
|
|
|
| ||
| to main PCB. |
|
|
| |
|
|
|
|
|
|
| E441 | ・ Problem with main PCB. |
|
| |
| Replace the control box. | ** |
| ||
| Error reading data |
|
| ||
|
|
|
| ||
| from main PCB. |
|
|
| |
|
|
|
|
| |
| E442 | Turn the power off and then back on again. |
|
| |
|
|
| ・ The data on the main PCB is corrupted. Corrupt data was initalized. |
|
|
| Problem with data |
|
|
| |
| on main PCB. |
|
|
| |
| E451 | ・ Data could not be correctly written to the panel when adjusting the needle up stop |
|
| |
| position. |
|
| ||
| Error writing data | Repeat the write operation. |
|
| |
| to head detector | ・ Alternatively, turn the power off and then back on again to reset the machine. |
|
| |
| unit. |
|
|
|
|
40 |