4-1. Switching the 4-column display

The 4-column data in the display can be changed to one of the following three statuses each time the SEL key is pressed. Stitch number display or no display Sewing speed display Counter display

When the sewing speed display/counter display appears, you can press the FUNC key to switch to another display.

 

Display mode

 

 

 

 

Four columns display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stitch number

 

 

 

ON

ABCD stitch number display

 

 

 

 

display

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sewing speed

ON

 

 

 

Maximum sewing speed setting value

 

 

 

 

 

 

 

 

 

 

 

 

 

display

ON

 

 

ON

Start backtack sewing speed setting value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

Lower thread counter value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing

 

 

Lower thread counter warning enabled

 

 

 

 

Counter display

 

 

 

 

 

 

 

 

 

ON

ON

 

 

Thread trimming counter value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

ON

Needle replacement counter value

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flashing

 

Flashing

Needle replacement counter warning enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0502D

0503D

0504D

4-2. Setting the sewing speed

 

 

 

 

 

4-2-1. Setting the maximum sewing speed

 

 

 

 

 

 

 

 

1 Press the SEL key so that the SPEED indicator is illuminated.

The maximum sewing speed setting value

 

 

 

 

 

 

will appear in the four columns of the

 

 

 

 

 

 

 

 

display.

 

 

 

 

 

 

 

0505D

 

 

 

 

 

2 Press the A

or B

key to change the setting value.

When the B

key is pressed, the setting

 

 

 

increases by 100.

 

 

 

When the A

key is pressed, the setting

 

 

 

decreases by 100.

 

 

 

NOTE:

 

 

 

 

The setting range is from 220 to 4000

 

 

 

sti/min.

 

0506D

S-7000DD