| 7. STANDARD ADJUSTMENTS | |
|
| ||
7. STANDARD ADJUSTMENTS | |||
|
|
| |
| CAUTION |
| |
Maintenance and inspection of the sewing machine | Turn off the power switch and disconnect the power |
| |
should only be carried out by a qualified technician. | cord from the wall outlet at the following times, |
| |
Ask your Brother dealer or a qualified electrician to | otherwise the machine may operate if the treadle is |
| |
depressed by mistake, which could result in injury. |
| ||
carry out any maintenance and inspection of the |
| ||
・ When carrying out inspection, adjustment and |
| ||
electrical system. |
|
| |
If any safety devices have been | removed, be | maintenance |
|
・ When replacing consumable parts such as the |
| ||
absolutely sure to | their original |
| |
rotary hook and knife |
| ||
positions and check that they operate correctly |
| ||
|
| ||
before using the machine. |
| Always be sure to turn off the power switch and then |
|
Secure the table so that it will not move when tilting | wait one minute before opening the motor cover. If |
| |
back the machine head. If the table moves, it may | you touch the surface of the motor, it may cause |
| |
crush your feet or cause other injuries. |
| burns. |
|
Use both hands to hold the machine head when | If the power switch needs to be left on when carrying |
| |
tilting it back or returning it to its original position. If | out some adjustment, be extremely careful to |
| |
only one hand is used, the weight of the machine | observe all safety precautions. |
| |
head may cause your hand to slip, and your hand |
|
| |
may get caught. |
|
|
|
7-1. Adjusting arm thread guide R
Becomes greater | Becomes less |
|
|
|
|
The standard position of arm thread guide R (1) is the position where the screw (2) is in the center of the adjustable range for arm thread guide R (1).
NOTE:
To adjust the position, loosen the screw (2) and then move arm thread guide R (1).
・When sewing thick material, move arm thread guide R
(1)to the left. (The thread
・When sewing thin material, move arm thread guide R
(1)to the right. (The thread
0533D