OPTIONS AND ACCESSORIES

569J* OPTIONS AND ACCESSORIES

ITEM

OPTION*

ACCESSORY†

Disconnect Switch (non-fused)}

X

 

 

 

 

Special--- coated Coil Protection

X

 

Convenience Outlet (115-v)**

X

 

 

 

 

Low Ambient Temperature

X

X

MotorMaster Ir Control

 

 

Wired Condenser Coil Grille (Novation 07 --- 14 models only)

 

X

 

 

 

Louvered Hail Guard

X

X

 

 

 

Programmable Thermostats

 

X

 

 

 

*Factory-installed option.

Field-installed accessory.

} Non---fused disconnect switch cannot be used when unit MOCP electrical rating exceeds 80 amps.

**Powered and non---powered versions available

569J* factory-installed options

CONDENSER COIL OPTIONS

Coil Coating Application - Novation Coils

 

 

 

Environment

 

 

Coil Description

 

 

 

 

 

 

Standard

Mild Coastal

Moderate

Severe

Industrial

Industrial &

 

Non---Corrosive

Coastal

Coastal

Coastal

 

 

 

 

 

 

 

 

 

 

Alum Fin / Alum Tube

X

 

 

 

 

 

 

 

 

 

 

 

 

E--- Coated Al / Al

 

X

X

X

X

X

 

 

 

 

 

 

 

NOTE: E--- Coat is only available and must be used in any non--- standard environment listed above.

 

 

Coil Coating Application - Round Tube/Plate Fin Coils

(07,08, 12, 16, 25 models)

Enviro ---ShieldDescription

 

 

Environment

 

 

Standard

Mild Coastal

Moderate

Severe

Industrial

Industrial &

 

Non---Corrosive

Coastal

Coastal

Coastal

 

 

 

 

 

 

 

 

 

 

Alum Fin / Cu Tube

X

 

 

 

 

 

Pre--- Coated Al / Cu

 

X

 

 

 

 

E--- Coated Al / Cu

 

 

 

 

X

X

Cu / Cu

 

 

X

X

 

 

NOTE: Refer to the Guide Specifications for further detail.

569J

E-coated aluminum-fin coils have a flexible and durable epoxy coating uniformly applied to all coil surfaces. Unlike brittle phenolic dip and bake coatings, E-coating provides superior protection with unmatched flexibility, edge coverage, metal adhesion, thermal performance, and most importantly, corrosion resistance.

E-coated coils provide this protection since all coil surfaces are completely encapsulated from environmental contamination. This coating is especially suitable in industrial environments.

Pre-coated coils (RTPF coils only) provide protection in mild coastal environments.

–20_F (–29_C) low-ambient temperature kit option (MotorMaster Ir) controls outdoor-fan motor operation to maintain the correct head pressure at low outdoor ambient temperatures.

Louvered hail guard package protects coils against damage from flying debris and hail.

115-v convenience outlet is used to power electric drills, lights, and refrigerant recovery machines. This means that a separate 115-v power supply is no longer necessary.

Non-fused disconnect switch is used to remove power locally at the condensing unit. This switch also includes a power lockout capability to protect the service person. This lockout switch saves the service person time and effort because there is no need to access a distant disconnect switch while servicing the unit.

11

Page 11
Image 11
Bryant manual 569J* factory-installed options, 569J* Options and Accessories, Condenser Coil Options