OPTIONS AND ACCESSORIES (cont)

POWER EXHAUST (180-300 SHOWN)

ACCUSENSOR III

SENSOR

+

When used with accessory/optional economizer, the power exhaust accessory helps to relieve building over-pressurization.

NOTE: This accessory is not available with horizontal supply adapter.

Accusensor economizer controls help provide efficient, economical economizer operation. Accusensor II solid-state enthalpy control in- cludes the logic and one sensor to calculate both dry- and wet-bulb of the outdoor air to provide an accurate enthalpy reading on 036-150 units. It then decides when to energize the economizer based on this reading. The 180-300 unit economizer provides the decision-making function internally, and requires one Accusensor III sensor for solid-state enthalpy sensing. A second Accusensor III sensor (required for all units for differential enthalpy sensing) compares outdoor temperature and hu- midity to return-air temperature and humidity and determines the most economical mixture of air (purchased in addition to enthalpy control [sizes 036-150] or to ®rst solid-state enthalpy sensor [sizes 180-300] for differential enthalpy sensing).

THERMOSTAT

H

C

Thermostat (24 v) provides one- or 2-stage cooling for control of unit. Matching subbases are available with or without tamperproof switches and automatic changeover.

16

Page 16
Image 16
Bryant 580D manual Accusensor Control, Only, Power Exhaust 180-300 Shown Accusensor Sensor, Thermostat