Bryant manual PERFORMANCE DATA cont, 580D060 5 TONS Ð STANDARD MOTOR DIRECT DRIVE

Models: 580D

1 72
Download 72 pages 58.37 Kb
Page 33
Image 33
580D060 (5 TONS) Ð STANDARD MOTOR (DIRECT DRIVE)

PERFORMANCE DATA (cont)

FAN PERFORMANCE Ð 580D036-150 VERTICAL DISCHARGE UNITS (cont)

580D060 (5 TONS) Ð STANDARD MOTOR (DIRECT DRIVE)

Air¯ow

 

 

 

Low Speed

 

 

 

 

 

 

 

 

Medium Speed

 

 

 

 

 

 

 

High Speed

 

 

 

 

208 V

 

 

 

230, 460, 575 V

 

 

 

208 V

 

230, 460, 575 V

 

 

 

208 V

 

230, 460, 575 V

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

Esp

Bhp

 

Watts

Esp

Bhp

 

Watts

Esp

Bhp

 

Watts

Esp

 

Bhp

 

Watts

Esp

Bhp

 

Watts

Esp

Bhp

 

Watts

1500

0.69

0.67

 

750

 

1.01

0.71

 

791

 

1.00

0.70

 

782

 

1.20

 

0.76

 

845

 

1.22

0.79

 

875

 

1.28

0.85

 

949

1600

0.49

0.70

 

780

 

0.85

0.74

 

824

 

0.85

0.74

 

821

 

1.06

 

0.79

 

883

 

1.09

0.82

 

913

 

1.17

0.89

 

988

1700

0.29

0.73

 

810

 

0.70

0.77

 

857

 

0.70

0.77

 

861

 

0.93

 

0.83

 

921

 

0.97

0.85

 

950

 

1.06

0.92

 

1027

1800

0.09

0.75

 

839

 

0.54

0.80

 

891

 

0.55

0.81

 

900

 

0.80

 

0.86

 

959

 

0.84

0.89

 

988

 

0.95

0.96

 

1066

1900

Ð

Ð

 

Ð

0.39

0.83

 

924

0.40

0.84

 

940

0.67

0.90

 

997

0.72

0.92

 

1025

0.84

0.99

 

1105

2000

Ð

Ð

 

Ð

0.23

0.86

 

957

0.25

0.88

 

979

0.54

0.93

 

1035

0.59

0.95

 

1063

0.73

1.03

 

1144

2100

Ð

Ð

 

Ð

0.08

0.89

 

990

0.10

0.91

 

1018

0.41

0.96

 

1073

0.46

0.99

 

1101

0.62

1.06

 

1183

2200

Ð

Ð

 

Ð

Ð

Ð

Ð

 

Ð

Ð

 

Ð

 

0.28

1.00

 

 

 

 

1111

0.34

1.02

 

1138

0.51

1.10

 

1222

2300

Ð

Ð

 

Ð

Ð

Ð

Ð

 

Ð

Ð

 

Ð

 

0.15

1.03

 

1149

 

0.21

1.06

 

1176

 

0.40

1.13

 

1261

 

 

2400

Ð

Ð

 

Ð

Ð

Ð

Ð

 

Ð

Ð

 

Ð

 

0.02

1.07

 

1187

 

0.09

1.09

 

1213

 

0.29

1.17

 

1300

 

 

2500

Ð

Ð

 

Ð

Ð

Ð

Ð

 

Ð

Ð

 

Ð

 

Ð

Ð

 

Ð

Ð

Ð

Ð

 

0.18

1.20

1340

 

 

 

 

 

LEGEND

Bhp

Ð Brake Horsepower Input to Fan

Esp

Ð

External Static Pressure (in. wg)

FIOP

Ð

Factory-Installed Option

NOTES:

1.Values include losses for ®lters, unit casing, and wet coils. See page 52 for accessory/FIOP static pressure information.

2.Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with con®dence. Using your fan motors up to the wattage ratings shown will not result in nuisance tripping or premature failure. Unit warranty will not be affected. See Evaporator-Fan Motor Performance table on page 55 for additional information.

3.Use of a ®eld-supplied motor may affect wire sizing. Contact your local representative for details.

580D060 (5 TONS) Ð ALTERNATE MOTOR (BELT DRIVE)*

Air¯ow

 

 

 

 

 

 

 

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

0.1

 

 

 

 

0.2

 

 

 

 

0.4

 

 

 

0.6

 

 

0.8

 

 

1.0

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

 

 

Rpm

Bhp

Watts

 

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

Rpm

Bhp

Watts

1500

750

0.36

368

 

 

808

0.42

429

 

914

 

0.56

 

572

1001

0.69

705

1084

0.85

869

1168

1.01

1032

1600

794

0.42

429

 

 

846

0.49

501

 

950

 

0.64

 

654

1034

0.78

797

1111

0.94

961

1194

1.11

1134

1700

839

0.50

511

 

 

884

0.57

582

 

983

 

0.72

 

736

1068

0.88

899

1145

1.03

1053

1218

1.21

1237

1800

885

0.58

593

 

 

924

0.66

674

 

1018

 

0.82

 

838

1105

0.98

1001

1179

1.13

1155

1246

1.32

1349

1900

932

0.68

695

 

 

965

0.76

777

 

1057

 

0.92

 

940

1143

1.10

1124

1212

1.26

1288

1280

1.43

1461

2000

979

0.78

797

 

 

1008

0.87

889

 

1096

 

1.04

 

1063

1177

1.22

1247

1247

1.40

1431

1300

1.57

1604

2100

1026

0.89

910

 

 

1051

0.99

1012

 

1136

 

1.17

 

1196

1210

1.35

1380

1284

1.54

1574

1347

1.72

1758

2200

1074

1.02

1042

 

 

1095

1.12

1145

 

1173

 

1.30

 

1328

1245

1.49

1523

1322

1.70

1737

1380

1.89

1931

2300

1122

1.16

1185

 

 

1140

1.26

1288

 

1210

 

1.47

 

1502

1284

1.65

1686

1356

1.80

1901

1418

2.07

2115

2400

1170

1.30

1328

 

 

1185

1.41

1441

 

1249

 

1.61

 

1645

1323

1.80

1860

1389

2.03

2074

1456

2.26

2310

2500

1218

1.46

1492

 

 

1231

1.57

1604

 

1289

 

1.78

 

1819

1363

2.00

2044

1424

2.22

2269

1500

2.45

2504

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

580D060 (5 TONS) Ð ALTERNATE MOTOR (BELT DRIVE)* (cont)

 

 

 

 

 

 

 

 

 

 

Air¯ow

 

 

External Static Pressure (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

1.2

 

 

 

 

1.4

 

 

 

 

1.6

 

 

 

 

 

 

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

Bhp

Watts

 

 

Rpm

Bhp

Watts

 

Rpm

 

Bhp

 

Watts

 

 

 

 

 

 

 

 

 

1500

1199

1.19

1216

 

 

1226

1.46

1492

 

1250

 

1.69

 

1757

 

 

 

 

 

 

 

 

 

1600

1263

1.28

1308

 

 

1275

1.49

1523

 

1299

 

1.78

 

1800

 

 

 

 

 

 

 

 

 

1700

1295

1.39

1420

 

 

1351

1.58

1615

 

1352

 

1.80

 

1850

 

 

 

 

 

 

 

 

 

1300

1319

1.52

1553

 

 

1389

1.71

1747

 

1435

 

1.91

 

1952

 

 

 

 

 

 

 

 

 

1900

1343

1.64

1676

 

 

1415

1.80

1891

 

1478

 

2.05

 

2095

 

 

 

 

 

 

 

 

 

2000

1374

1.77

1809

 

 

1438

1.99

2034

 

1505

 

2.21

 

2258

 

 

 

 

 

 

 

 

 

2100

1409

1.91

1952

 

 

1465

2.14

2167

 

Ð

 

Ð

 

Ð

 

 

 

 

 

 

 

 

 

2200

1442

2.08

2126

 

 

1498

2.30

2350

 

Ð

 

Ð

 

Ð

 

 

 

 

 

 

 

 

 

2300

1475

2.26

2310

 

 

Ð

Ð

Ð

Ð

Ð

 

Ð

 

 

 

 

 

 

 

 

 

 

 

2400

1565

2.47

2524

 

 

Ð

Ð

Ð

Ð

Ð

 

Ð

 

 

 

 

 

 

 

 

 

 

 

2500

Ð

Ð

Ð

Ð

Ð

Ð

Ð

 

Ð

 

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

Bhp

Ð Brake Horsepower Input to Fan

FIOP

Ð

Factory-Installed Option

Watts

Ð

Input Watts to Motor

*Motor drive range is 900 to 1300 rpm. All other rpms require a ®eld- supplied drive.

NOTES:

1.Boldface indicates ®eld-supplied motor and drive are required.

2.Values include losses for ®lters, unit casing, and wet coils. See page 52 for accessory/FIOP static pressure information.

3.Maximum continuous bhp is 1.80 and the maximum continuous watts are 1921. Extensive motor and electrical testing on these units ensures that the full range of the motor can be utilized with con®- dence. Using your fan motors up to the wattage ratings shown will not result in nuisance tripping or premature motor failure. Unit war- ranty will not be affected. See Evaporator-Fan Motor Performance table on page 55 for additional information.

4.Use of a ®eld-supplied motor may affect wire sizing. Contact your local representative for details.

5.Interpolation is permissible. Do not extrapolate.

33

Page 33
Image 33
Bryant manual PERFORMANCE DATA cont, 580D060 5 TONS Ð STANDARD MOTOR DIRECT DRIVE