PERFORMANCE DATA

COOLING CAPACITIES

580D036 (3 TONS)

Temp (F)

 

Air Entering Evaporator Ð Cfm/BF

 

Air Entering

900/0.11

1200/0.14

1500/0.17

Condenser

 

Air Entering Evaporator Ð Ewb (F)

 

(Edb)

 

 

 

 

 

 

 

 

 

72

67

62

72

67

62

72

67

62

 

TC

42.8

38.9

35.0

44.8

40.8

37.0

45.8

41.9

38.2

75SHC 20.0 24.5 28.7 21.8 27.5 32.8 23.0 30.0 36.0

kW 2.91 2.81 2.70 2.99 2.88 2.78 3.02 2.92 2.82

TC

40.8

36.9

33.3

42.5

38.7

35.0

43.6

39.9

36.1

85SHC 19.4 23.7 27.9 21.0 26.8 31.8 22.6 29.7 35.1

kW 3.14 3.01 2.90 3.20 3.08 2.97 3.24 3.14 3.02

TC

38.7

34.9

31.4

40.4

36.6

33.0

41.4

37.6

34.1

95SHC 18.6 22.9 27.0 20.3 26.0 30.9 22.0 28.8 34.0

kW 3.35 3.21 3.09 3.42 3.29 3.16 3.47 3.35 3.22

TC

36.5

32.8

29.2

38.1

34.3

30.9

39.0

35.2

32.4

105SHC 17.8 22.1 25.9 19.6 25.2 29.8 21.2 28.0 32.3

kW 3.55 3.41 3.27 3.63 3.49 3.35 3.68 3.54 3.43

TC

34.3

30.7

26.9

35.7

32.1

28.8

36.5

32.9

30.6

115SHC 17.0 21.3 24.8 19.0 24.4 28.8 20.5 27.1 30.6

kW 3.76 3.60 3.45 3.84 3.68 3.54 3.88 3.74 3.64

580D048 (4 TONS)

Temp (F)

 

Air Entering Evaporator Ð Cfm/BF

 

Air Entering

1200/0.12

1600/0.15

2000/0.18

Condenser

 

Air Entering Evaporator Ð Ewb (F)

 

(Edb)

 

 

 

 

 

 

 

 

 

72

67

62

72

67

62

72

67

62

 

TC

57.9

53.1

48.3

60.4

55.9

51.3

62.2

57.3

52.9

75SHC 27.2 33.3 39.2 29.4 37.2 44.8 31.4 40.3 49.1

kW 4.07 3.93 3.79 4.17 4.03 3.90 4.24 4.08 3.96

TC

55.7

50.8

45.3

57.7

53.4

48.5

59.4

55.0

50.2

85SHC 26.4 32.5 37.8 28.4 36.7 43.6 30.5 40.3 47.9

kW 4.40 4.24 4.08 4.47 4.35 4.20 4.54 4.42 4.25

TC

52.9

48.1

42.5

55.2

50.5

45.7

56.7

52.0

47.4

95SHC 25.5 31.5 36.4 27.6 35.6 42.2 29.7 39.2 46.7

kW 4.70 4.54 4.36 4.78 4.63 4.47 4.87 4.70 4.56

TC

50.1

45.3

39.8

52.3

47.6

42.8

53.6

48.9

44.9

105SHC 24.4 30.3 35.1 26.7 34.5 40.7 28.8 38.1 44.6

kW 5.00 4.81 4.62 5.10 4.91 4.73 5.17 4.99 4.84

TC

47.3

42.6

37.2

49.3

44.6

40.0

50.5

45.9

42.4

115SHC 23.4 29.2 33.7 25.9 33.3 39.3 27.8 37.1 42.4

kW 5.30 5.07 4.88 5.42 5.19 4.99 5.48 5.28 5.12

580D060 (5 TONS)

Temp (F)

 

Air Entering Evaporator Ð Cfm/BF

 

Air Entering

1500/0.07

2000/0.09

2500/0.12

Condenser

 

Air Entering Evaporator Ð Ewb (F)

 

(Edb)

 

 

 

 

 

 

 

 

 

72

67

62

72

67

62

72

67

62

 

TC

71.0

63.8

55.4

74.5

67.2

59.2

76.5

69.7

62.1

75SHC 33.9 41.5 47.9 37.4 47.4 55.8 40.6 52.8 61.8

kW 5.04 4.82 4.62 5.20 4.97 4.76 5.29 5.06 4.87

TC

69.2

61.0

54.2

72.9

65.6

57.2

75.2

68.1

61.5

85SHC 33.4 40.5 47.3 37.0 46.9 54.9 40.1 52.3 61.3

kW 5.50 5.27 5.02 5.66 5.41 5.18 5.75 5.50 5.29

TC

65.5

56.6

50.4

69.4

60.9

53.1

71.2

63.3

57.8

95SHC 32.1 38.8 45.6 35.8 45.3 52.6 39.1 50.9 57.8

kW 5.88 5.62 5.37 6.01 5.76 5.53 6.12 5.87 5.67

TC

61.9

53.1

47.1

65.4

56.6

50.5

67.1

58.8

54.5

105SHC 30.8 37.5 44.1 34.5 43.7 50.2 37.9 49.3 54.5

kW 6.25 5.99 5.72 6.38 6.13 5.91 6.50 6.23 6.06

TC

58.2

49.7

43.7

61.4

52.3

47.8

63.0

54.3

51.2

115SHC 29.5 36.1 42.5 33.2 42.1 47.8 36.7 47.6 51.2

 

 

kW

6.63

6.35

6.08

6.75

6.49

6.29

6.88

6.59

6.46

 

 

Standard Ratings

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

BF

Ð Bypass Factor

 

 

 

 

 

 

 

Edb

Ð Entering Dry-Bulb

 

 

 

 

 

 

 

Ewb

Ð Entering Wet-Bulb

 

 

 

 

 

 

kW

Ð Compressor Motor Power Input

 

 

 

 

Ldb

Ð Leaving Dry-Bulb

 

 

 

 

 

 

 

Lwb

Ð Leaving Wet-Bulb

 

 

 

 

 

 

 

SHC Ð Sensible Heat Capacity (1000 Btuh) Gross

 

 

TC

Ð Total Capacity (1000 Btuh) Gross

 

 

 

 

NOTES:

1.Direct interpolation is permissible. Do not extrapolate.

2.The following formulas may be used:

sensible capacity (Btuh)

tldb = tedb

1.10 x cfm

tlwb = Wet-bulb temperature corresponding to enthalpy of air leav- ing evaporator coil (hlwb)

total capacity (Btuh)

hlwb = hewb

4.5 x cfm

Where: hewb = Enthalpy of air entering evaporator coil

3. The SHC is based on 80 F edb temperature of air entering evapo- rator coil.

Below 80 F edb, subtract (corr factor x cfm) from SHC. Above 80 F edb, add (corr factor x cfm) to SHC.

Correction Factor = 1.10 x (1 − BF) x (edb − 80).

580D072 (6 TONS)

Temp (F)

 

 

 

Air Entering Evaporator Ð Cfm/BF

 

 

 

Air Entering

1800/0.06

 

2100/0.08

2400/0.09

 

3000/0.11

Condenser

 

 

 

Air Entering Evaporator Ð Ewb (F)

 

 

 

(Edb)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

72

67

62

 

72

67

62

72

67

62

 

72

67

62

 

 

 

 

 

TC

86.6

80.0

73.6

 

87.8

80.3

73.2

90.8

84.1

77.2

 

93.2

86.6

79.7

75

SHC

42.2

52.3

62.2

 

43.0

53.9

65.5

46.5

59.6

71.6

 

50.1

66.4

78.7

 

kW

5.48

5.33

5.21

 

5.69

5.50

5.32

5.59

5.44

5.29

 

5.66

5.51

5.35

 

TC

84.1

77.4

71.0

 

84.0

77.2

69.5

87.8

81.2

74.5

 

90.1

83.5

77.3

85

SHC

41.4

51.3

61.1

 

41.7

53.1

64.0

45.5

58.6

70.3

 

49.4

65.4

76.7

 

kW

6.17

6.00

5.85

 

6.21

6.04

5.83

6.27

6.11

5.94

 

6.35

6.19

6.02

 

TC

81.6

74.7

68.5

 

81.0

73.5

66.3

84.8

78.2

71.8

 

87.0

80.4

74.8

95

SHC

40.6

50.3

60.0

 

40.8

 

62.8

44.6

57.6

69.1

 

48.7

64.5

74.7

51.8

 

kW

6.86

6.67

6.49

 

6.78

6.54

6.33

6.95

6.77

6.59

 

7.03

6.86

6.69

 

TC

78.4

71.8

65.6

 

76.8

69.7

62.5

81.6

74.9

68.9

 

83.3

76.9

72.1

105

SHC

39.4

49.2

58.7

 

39.4

50.3

61.1

43.5

56.4

67.4

 

47.4

63.1

72.0

 

kW

7.60

7.39

7.20

 

7.30

7.05

6.80

7.72

7.50

7.31

 

7.77

7.59

7.41

 

TC

75.1

68.7

62.5

 

72.5

65.5

58.7

78.0

71.5

66.1

 

79.5

73.3

69.3

115

SHC

38.1

47.9

57.2

 

37.9

48.7

58.7

42.3

55.1

65.5

 

46.3

61.6

69.2

 

kW

8.36

8.14

7.93

 

7.81

7.53

7.27

8.49

8.25

8.06

 

8.55

8.33

8.18

26

Page 26
Image 26
Bryant 580D manual Performance Data Cooling Capacities, Shc