Using LANVIEW

 

 

 

 

 

Table 4-1 LANVIEW LEDs (Continued)

 

 

 

 

LED

Color

State

Recommended Action

 

 

 

 

CPU

Off

Power off.

Power up device.

 

 

 

 

 

Red

Blinking. Hardware

Contact Cabletron Systems for technical

 

 

failure has occurred.

support.

 

 

 

 

 

 

Solid. Resetting, normal

If the LED remains red for several minutes,

 

 

power up reset.

contact Cabletron Systems for technical

 

 

 

support.

 

 

 

 

 

Amber

Blinking. Crippled.

Contact Cabletron Systems for technical

 

 

 

support.

 

 

 

 

 

 

Solid. Testing.

If the LED remains amber for several

 

 

 

minutes, contact Cabletron Systems for

 

 

 

technical support.

 

 

 

 

 

Green

Solid. Functional.

None.

 

 

 

 

 

Amber

Booting. Blinks amber

None.

 

and

and green while booting.

 

 

Green

 

 

 

 

 

 

RX

Off

No link.

None.

(Receive)

 

No activity or port in

 

 

 

standby. Port enabled or

 

 

 

disabled.

 

 

 

 

 

 

Green

Solid. Link, port enabled,

None.

 

 

no activity.

 

 

 

 

 

 

 

Blinking. Link, port

None.

 

 

disabled.

 

 

 

 

 

 

Amber

Flashing. Link, port

None.

 

 

enabled, activity.

 

 

 

 

 

 

Red

Solid. Diagnostic failure.

Contact Cabletron Systems for assistance.

 

 

 

 

Troubleshooting 4-3

Page 43
Image 43
Cabletron Systems 2200 manual No link