SmartCell 6A000/ZX-250 Reference Manual 2-103
Console Commands
Lo
g
Use Log to control log message recording onto the log message buffer.
Operators
start, stop
Parameters
This command has no parameters. Just type start log or stop log at the switch prompt.
Descriptions
Examples
switch_prompt # start log
Enabling logging into buffer at time:165:41:09:486
switch_prompt #
switch_prompt # stop log
Disabling logging into buffer at time:166:01:55:332
switch_prompt #
SERVER SVC
X
Operator Parameters/Permissions Description
start log Administrator Enables messages to be logged into the log message
buffer.After entering this command, messages begin logging
to the buffer, which could lead to alarms being generated,
depending on which flags were set with modify
logalarmmask (see “LogAlarmMask”).You can also print
messages directly to the console instead of the log.
stop log Administrator Disabl es message logging into the buffer. After entering this
command, no alarms are generated from log messages.
Logging can be enabled again by entering start log.