5.18SWITCH CONFIGURATION SCREEN

Chapter 5: Local Management

5.18SWITCH CONFIGURATION SCREEN

NOTE

The Switch Configuration screen will not be available if the operational mode of the module has been set to SECURE FAST VLAN. This screen may only be used by modules configured to operate as 802.1D or 802.1Q switches.

The Switch Configuration screen, Figure 5-24, provides the basic setup options to modify switch operations in your network.

Access the Switch Configuration screen from the Module Configuration Menu screen by using the arrow keys to highlight the SWITCH CONFIGURATION menu item and pressing ENTER. The Switch Configuration screen, Figure 5-24, displays ports 1 through 8. To view or edit the fields for ports 9 to 12, highlight [9-12]at the bottom of the screen and press the ENTER key.

NOTE

Ports 7 and 8 on the Switch Configuration screen represent the optional Fast Ethernet Interface Modules available for the 6H122-08.

Ports 9 through 12 represent the backplane connections that the 6H122-08 has with the 6C105 chassis. The module has a direct connection to every other slot in the chassis.