Chapter 9: VRRP Configuration Guide

ip-redundancy show

The ip-redundancy show command reports information about a VRRP configuration.

To display information about all virtual routers on interface int1:

ssr# ip-redundancy show vrrp interface int1

VRRP Virtual Router 100 - Interface int1

------------------------------------------

Uptime

0 days, 0 hours, 0 minutes, 17 seconds.

State

Backup

Priority

100 (default value)

Virtual MAC address

00005E:000164

Advertise Interval

1 sec(s) (default value)

Preempt Mode

Enabled (default value)

Authentication

None (default value)

Primary Address

10.8.0.2

Associated Addresses

10.8.0.1

 

100.0.0.1

VRRP Virtual Router 200 - Interface int1

------------------------------------------

Uptime

0 days, 0 hours, 0 minutes, 17 seconds.

State

Master

Priority

255 (default value)

Virtual MAC address

00005E:0001C8

Advertise Interval

1 sec(s) (default value)

Preempt Mode

Enabled (default value)

Authentication

None (default value)

Primary Address

10.8.0.2

Associated Addresses

10.8.0.2

102

SmartSwitch Router User Reference Manual

Page 128
Image 128
Cabletron Systems 9032578-05 manual Ip-redundancy show, Ssr# ip-redundancy show vrrp interface int1