Cabletron Systems 9032578-05 manual 326

Models: 9032578-05

1 398
Download 398 pages 17.39 Kb
Page 352
Image 352

Chapter 23: RMON Configuration Guide

Check the following fields on the rmon show status command output:

ssr# rmon show status RMON Status

-----------

* RMON is ENABLED 1

* RMON initialization successful.

 

 

2

 

 

+--------------------------

 

+

 

RMON Group Status

 

+-------

+

--------+---------

+

 

Group Status Default

 

+-------

+

--------+---------

+

 

Lite

On

Yes

4

+-------

+

--------+---------

+

 

Std

On

Yes

 

+-------

+

--------+---------

+

 

Pro

On

Yes

 

+-------

+

--------+---------

+

 

RMON is enabled on: et.5.1, et.5.2, et.5.3, et.5.4, et.5.5, et.5.6, et.5.7, et.5.8 3

RMON Memory Utilization

 

 

-----------------------

 

 

Total Bytes Available:

48530436

 

Total Bytes Allocated to RMON:

4000000

 

Total Bytes Used:

2637872

5

Total Bytes Free:

1362128

 

1.Make sure that RMON has been enabled on the SSR. When the SSR is booted, RMON is off by default. RMON is enabled with the rmon enable command.

2.Make sure that at least one of the RMON support levels—Lite, Standard, or Professional—is turned on with the rmon set litestandardprofessional command.

3.Make sure that RMON is enabled on the port for which you want statistics. Use the rmon set ports command to specify the port on which RMON will be enabled.

4.Make sure that the control table is configured for the report that you want. Depending upon the RMON group, default control tables may be created for all ports on the SSR. Or, if the RMON group is not one for which default control tables can be created, you will need to configure control table entries using the appropriate rmon command.

If you or your application are unable to create a control table row, check the snmp show status output for errors. Make sure that there is a read-write community string. Verify that you can ping the SSR and that no ACLs prevent you from using SNMP to access the SSR.

5.Make sure that RMON has not run out of memory.

326

SmartSwitch Router User Reference Manual

Page 352
Image 352
Cabletron Systems 9032578-05 manual 326