CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
117
Parameter ID 23 Parameter
Name #1 Analog Notch Filter Frequency
Data Central frequency of the first analog notch filter (Unit: Hz)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the central frequency of the first analog notch filter.
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter
Parameter ID 24 Parameter
Name #2 Analog Notch Filter Frequency
Data Central frequency of the second analog notch filter (Unit: Hz)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the central frequency of the second analog notch filter.
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter
Parameter ID 25 Parameter
Name #3 Analog Notch Filter Frequency
Data Central frequency of the third analog notch filter (Unit: Hz)
Return Value 0: Parameter setting successful
1: Parameter setting unsuccessful
Explanation This parameter is used to set the central frequency of the third analog notch filter.
The setting range is from 9750 to 42820 Hz.
Related
Command
/Parameter