Display of the Auto Tuning screen
Select the setting file (Definition File).
Setting files will be provided by Canon.
When necessary, select parameter files to load in the controller prior to tuning.
Check the “Load Parameter File before start” checkbox and specify the parameter file. Use in
situations when you want to load a parameter file and then carry out tuning.
Parameter files to be loaded will be prepared by the user. Refer to 9.5 for the file creation method.
Select the folder for results (Result Folder).
Tuning results will be saved.
Select the axis.
Select the axis connected to the motor and mirror that corresponds to the Definition File.