5.2. Analog Monitor Output Selecting
The analog monitor output can be switched to monitor various operation and signal statuses.
This switching can be executed from [Control Software] or [RS-232C command send].
Output contents
Terminal Monitor Board
Signal Name
Power-on
Selection
Signal Description Signal Level (At
Power-on)
2 (Axis 1)
6 (Axis 2)
A2 (Axis 1)
A6 (Axis 2)
Phase A of Encoder Head 1
Phase A of Encoder Head 2
Phase A of encoder after synthesis
* Positional deviation signal 1.5 mV / pulse
3 (Axis 1)
7 (Axis 2)
A3 (Axis 1)
A7 (Axis 2)
Position 0.091 mV / pulse
* Velocity 0.091 mV / pulse / 10
Coarse angle
Fine angle
4 (Axis 1)
8 (Axis 2)
A4 (Axis 1)
A8 (Axis 2)
Phase B of Encoder Head 1
Phase B of Encoder Head 2
Phase B of encoder after synthesis
* Target position 0.091 mV / pulse