CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
90
By pressing the SETUP button, operating conditions during FULL AUTO can be set. Usually default
parameter settings will operate correctly.
Frequency Frequency when measuring the frequency response
GAIN
Max Change Permissible change rate from the original gain setting value.
If this value is exceeded, the operation will be stopped with an error.
Target Range Adjustment takes place so the margin of error between both axis is
lower than this value.
Q
Fine Step Amount of step adjustment for Q
Max Change Permissible change rate from the original Q setting value.
If this value is exceeded, the operation will be stopped with an error.
Target Range Adjustment takes place so the margin of error between both axis is
lower than this value.