Operations
• Need to change the mechanical setting so that can operate in a range ±15°(Mechanical Angle) ,
when excute the auto tuning. Because that auto tuning program operate the motor in a range ±
15°(Mechanical Angle) .
• Turn OFF high-speed serial ①
• Select the Servo Setting tab ②
• Press Auto Tuning ③
• Input the password (canon)
②
③
①