CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
73
A response is necessary after confirming the error
details with the control software, or RS-232C
command ID = 15 error read.
LED5 ALARM display (for Axis 2)
This LED (red) is lit when a malfunction occurs with
the controller.
A response is necessary after confirming the error
details with the control software, or RS-232C
command ID = 15 error read.
LED6 DSP2 operation (for Axis 1)
Always lights in approximately 1 sec. intervals if
DSP2 start up correctly.
LED7 DSP2 operation (for Axis 2)
Always lights in approximately 1 sec. intervals if
DSP2 start up correctly.
Note: When connecting only one axis of the motor and operating the controller (GC-201), an error will
always occur for the axis that is not connected. As a result, either LED4 or LED5 will light up, however,
as there is no problem with the operation of the connected axis, use it as is.