CANON Digital Galvano Scanner System GM-1000 Series
Users Manual 1.20
74
6.3. Operation that Synchronizes with External Trigger Signal input (Raster Scan)
“4.3. Raster Scan” can be operated in synchronization with an external trigger signal.
The Movement Pattern
There are two kinds of movement patterns.
① (The raster scan of one coming and going operates whene ver the external trigger signal is input.)
② (The raster scan of one way operates whene ver the external trigger signal is input.)
① and ② operation pattern can be selected by RS-232C command (Command ID = 23 ‘Operation
Mode setting‘)
External Trigger Signal
Raster Scan position
(Current Angle Position)
Angle
Voltage
External Trigger Signal
Raster Scan position
(Current Angle Position)
Angle
Voltage