⑤ Servo ON/OFF Start or stop servo control.
⑥
High-speed serial
communication
selection
Select the high-speed serial communication command or RS232C
command input for position specification.
(For details, see 4.4. Position Command Input by High-speed
Serial Communication)
(Start = High-speed serial communication, OFF = RS-232C
command)
⑦ Tab selection
The screen of each function can be displayed by tab selection.
(A detailed explanation of the screen is shown when each function
is displayed.)
⑧ Control display This area displays the screen of each function selected by a tab at
⑦.
⑨ Status display
The controller status of two axes is displayed.
If press the alarm button during alarm light on, windows content the
alarm details will come up.
⑩ Alarm clear Clears the alarm. The alarm lamp turns off.
⑪ Soft reset button Press this button for soft reset.
⑫ Command input
screen
Allows direct command input.
⑬ DSP version
display
The version of the controller software is displayed.
During troubleshooting, the support staff may ask for the version