3.8.1 Final factory test pattern

Part 3: Operating Instructions

BJC-7100

3.8.1 Final factory test pattern

Print out printing pattern as Figure 3-21.

See that "BJC-7100 Vx.xxx" is printed at left top on the final factory test pattern. "BJ F800 Vx.xxx" is printed if the machine is set as model for Japan.

1)Enter to a service mode. See "3.8 Service Mode" (page 3-20).

2)Press the RESUME button once (ERROR indicator turns on).

3)Press the POWER button to print the final factory test pattern.

4)To quit printing the test pattern, press POWER button.

Figure 3-21 Service Mode Test Print (Sample)

3.8.2 Resetting EEPROM data

1) Total waste ink amount data reset

The data on total waste ink amount stored in the EEPROM is used for detecting when the waste ink absorbers are full. This data must therefore be reset when you replace the waste ink absorbers.

1)Enter to a service mode. See "Part 3: 3.8 Service Mode" (page 3-21)for details of replacing the waste ink absorbers.

2)Press the RESUME button twice (ERROR indicator turns off).

3)Press the POWER button to reset the total waste ink amount recorded in the

EEPROM.

4)After resetting the total waste ink amount, the printer automatically turns off.

2)All service data reset

If, when you replace the logic board, you do not intend to continue using the existing EEPROM data, reset all the service data in the EEPROM on the new logic board, and replace the waste ink absorbers and maintenance jet absorbers.

1)Enter to a service mode. See "Part 3: 3.8 Service Mode" (page 3-20).

2)Press the RESUME button three times. (the ERROR indicator turns on).

3)Press the POWER button to reset all service data recorded in the EEPROM.

4)After resetting the data, the printer automatically turns off.

The following data are reset:

Waste ink amount

Page count

Cartridge installation/removal count

Number of recovery operations

BJL command settings (to factory settings)