Part 5: Maintenance |
6.2.2 Action
a)Error displays
1.Print Position Correction Error
Buzzer: 8 times
ERROR indicator: Blinks twice
<Cause> During initialization, the carriage print position is not corrected. (The differential between the carriage travel in each direction is outside the correction range.)
Carriage unit, carriage belt, carriage cable, carriage shaft, guide rail, idler pulley, logic board
<Measure>
Visually check carriage drive.
OK?
•Check for paper jams, wear and tear and removal of carriage belt;
•Carriage with faulty idler pulley assembly operation;
•Carriage shaft distortion, scratches, insufficient lubrication, etc.
•Does the carriage move smoothly when moved manually?
See "4. 2. 2 Carriage unit" (page
No
Yes |
|
|
| |
|
| Service or replace | ||
|
|
| ||
|
|
| faulty part. | |
|
| |||
Reconnect power supply. | ||||
|
| |||
|
|
|
| |
|
|
|
|
Check operation |
| • Does the carriage motor run during initialization? | |||||||||||||||||||
of carriage drive. |
|
| • Is the carriage drive out of sync? |
|
|
| |||||||||||||||
|
|
|
|
| • Are there any problems in the carriage belt or idler pulley? | ||||||||||||||||
|
|
|
| • Are there any abnormal noises? |
|
|
| ||||||||||||||
OK? |
| No |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
Yes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
| A |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| *: See "CAUTION" on page | ||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| Measuring point | Sensor |
| Normal value |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| IC1 (MPU) | Open |
| Low level |
|
|
| ||||||||||
|
|
|
|
| Pin No. 28 |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| Closed |
| High level (sensing) |
|
|
| |||||||||||
|
|
|
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
Check home position |
| • Check the measuring point while manually moving | |||||||||||||||||||
sensor. |
|
| the carriage with the power ON. (This is easier with | ||||||||||||||||||
|
|
|
|
| the sheet feeder removed.) |
|
|
|
|
|
|
|
|
| |||||||
|
|
| No |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
OK? |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| Measuring point |
|
|
| ||||||||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
Yes |
|
|
|
|
|
|
| Carriage ribbon cable (28pin) | |||||||||||||
|
|
|
|
|
|
|
|
| Pin Nos. 6 and 7 |
|
|
| |||||||||
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
| Check carriage cable |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| conductivity. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
| 28 | 7 |
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| No |
|
|
| 1 | 6 |
| ||||||
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
| OK? |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
| Yes |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Replace logic board. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| Replace carriage unit. |
|
|
| Replace carriage cable. |
| ||||||||||||||
|
|
|
|
|
|
|
|
| |||||||||||||
• Faulty MPU | |||||||||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
• Faulty PCB |
| • Faulty carriage board. |
|
|
|
|
|
|
|
|
| ||||||||||
soldering/conductivity |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|