Part 5: Maintenance |
A
1 3 5 7
2 4 6 8
Check motor drive voltage.
Measuring point | Normal value | |
|
| |
Logic board CNPWR | 27.6 ± 1.5VDC (no load max 33V) | |
Pin No. 3 | ||
| ||
|
|
OK? Yes
No
Check power cable.
OK?
Yes
Replace AC adaptor.
•Check the connection and conductivity of the power cable that links the logic board with the AC adaptor.
Logic board side
No
AC adaptor side
Replace power cable.
Check carriage motor.
1
Red
Blue
Orange
Yellow
4
1 | A |
|
2 | B | Approx. |
3 | B | 8.3Ω/phase |
4A
Carriage motor
OK? Yes
Measuring point | Normal value | ||
|
|
| |
CNCR | Approx. 8.3Ω | ||
|
| ||
|
|
|
No
Replace logic board.
•Faulty motor driver IC
•Faulty MPU
•Faulty PCB soldering/conductivity
Replace carriage motor.