Table 9 - Keypad Directory
STATUS
|
|
|
|
|
| KEYPAD ENTRY |
| DISPLAY | 1 |
|
|
|
| COMMENT |
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
| Refer to Automatic Display Operation on page 28 |
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
| 2 ALARMS | I |
|
|
| X ALARMS |
|
| Number of Tripped Alarms |
|
|
| |||||||||
|
|
|
|
|
|
|
|
| ALARM X |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ALARM X |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ALARM X |
|
|
|
|
| Displays Tripped Alarms | |||||||
|
|
|
|
|
|
|
|
| ALARM X |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| ALARM X |
| > |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| 3 MODES |
|
|
|
|
| X MODES |
|
| Number of Modes in Effect |
|
|
| ||||||||
|
|
|
|
|
|
|
|
| MODE X |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| MODE X |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Displays Mode in Effect | ||||||
|
|
|
|
|
|
|
|
| MODE X |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| MODE X |
| > |
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||
|
| 4 STAGE |
|
|
|
|
| STAGE |
|
| Capacity | Staging | Information |
|
|
| ||||||
|
|
|
|
|
|
|
|
| S T A G E X |
|
| Number of Requested Stages |
|
|
| |||||||
|
|
|
|
|
|
|
|
| CAPT X |
|
| Percent | of Total | Capacity |
|
|
| |||||
|
|
|
|
|
|
|
|
| CAPA X |
|
| Percent Circuit A Capacity | 6;,; | |||||||||
|
|
|
|
|
|
|
|
| CAP0 X |
|
| Percent Circuit 6 Capacity | ||||||||||
|
|
|
|
|
|
|
|
| LMT X* |
|
| Demand | Limit | Set Point | ||||||||
|
|
|
|
|
|
|
|
| LOAD X* |
|
| Load |
| Limit Set | Point |
|
|
|
| |||
|
|
|
|
|
|
|
|
| CIRA X |
|
| Circuit A Compressor Relay Status | ||||||||||
|
|
|
|
|
|
|
|
| CIRB X |
|
| Circuit B Compressor Relay Status | ||||||||||
|
|
|
|
|
|
|
|
| S M Z | X |
|
| Load/Unload Factor for Compressors | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
| Factor = 1 Unloader Factor = 0 6 | |||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
5 | SET POINT |
|
|
|
|
| SET | POINT |
|
| Fluid |
| Set Point |
| Information |
|
|
| ||||
|
|
|
|
|
|
|
|
| SP x |
|
| Set | Point |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
| M S P | X |
|
| Modified Set Point = Set Point | + Reset | ||||||||
|
|
|
|
|
|
|
|
| TWX |
|
| Cooler | Leaving |
| Fluid | Temperature | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
| TEMPS |
|
| Temperature | Information |
|
|
| |||||||
6 | TEMPERATURE |
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
| EWTX |
|
| Cooler | Entering | Fluid | Temperature | |||||||
|
|
|
|
|
|
|
|
| L W T | X |
|
| Cooler | Leaving |
| Fluid | Temperature | |||||
|
|
|
|
|
|
|
|
| SCTA X |
|
| Circuit A Saturated Condenser Temperature | ||||||||||
|
|
|
|
|
|
|
|
| S S T A X |
|
| Circuit A Saturated Suction Temperature | ||||||||||
|
|
|
|
|
|
|
|
| CTA X |
|
| Compressor Al Suction Temperature | ||||||||||
|
|
|
|
|
|
|
|
| SHA X |
|
| Circuit A Suction Superheat |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| LEGEND |
|
|
|
|
|
| *Must be configured |
|
|
|
|
|
| ||||||
|
| CCN | - Carrier Comfort | Network |
|
| applicable |
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
|
| E X V | - Electronic Expansion Valve |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
| M O P | - Maximum Operating Pressure |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3 0