Table 14 Ð Fan Performance, 50EJ048 Ð Vertical Discharge Units

FOR EW UNITS, REDUCE NET AVAILABLE EXTERNAL STATIC PRESSURE BY 0.5 IN. WG

AIRFLOW

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

0.2

 

 

 

0.4

 

 

 

 

0.6

 

0.8

 

1.0

 

 

 

1.2

 

 

1.4

 

1.6

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Rpm

 

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

Rpm

 

 

Bhp

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

13,000

683

7.10

 

715

 

 

8.59

747

 

9.09

 

777

9.60

808

 

 

10.11

 

837

 

10.62

866

 

11.14

894

 

11.66

14,000

730

8.53

 

761

 

10.25

790

 

10.77

 

819

11.30

847

 

 

11.83

 

875

 

12.36

902

 

12.90

929

 

13.44

15,000

778

10.14

 

807

 

12.10

834

 

12.65

 

862

13.19

888

 

 

13.75

 

915

 

14.30

941

 

14.86

966

 

15.42

16,000

826

11.93

 

853

 

14.15

879

 

14.72

 

905

15.29

931

 

 

15.86

 

955

 

16.44

980

 

17.01

1004

 

17.59

17,000

875

13.90

 

900

 

16.42

925

 

17.01

 

949

17.60

973

 

 

18.19

 

997

 

18.78

1020

 

19.38

1043

 

19.98

18,000

923

16.06

 

947

 

18.90

971

 

19.51

 

994

20.12

1017

 

 

20.73

 

1039

 

21.34

1062

 

21.96

1084

 

22.58

19,000

972

18.42

 

995

 

21.61

1017

 

22.24

 

1039

22.87

1061

 

 

23.50

 

1083

 

24.13

1104

 

24.76

1125

 

25.40

20,000

1021

20.98

 

1042

 

24.55

1064

 

25.20

 

1085

25.85

1106

 

 

26.50

 

1126

 

27.15

1147

 

27.80

1167

 

28.46

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

1.8

 

 

 

2.0

 

 

 

 

2.2

 

2.4

 

2.6

 

 

 

2.8

 

 

3.0

 

3.2

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Rpm

 

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

Rpm

 

 

Bhp

 

Rpm

 

Bhp

Rpm

 

Bhp

Rpm

 

Bhp

13,000

921

12.18

 

948

 

12.71

975

 

13.24

 

1001

13.77

1026

 

 

14.30

 

1051

 

14.84

1076

 

15.39

1100

 

15.93

14,000

955

13.98

 

981

 

14.53

1006

 

15.08

 

1031

15.63

1056

 

 

16.18

 

1080

 

16.74

1103

 

17.30

1127

 

17.86

15,000

991

15.98

 

1015

 

16.54

1040

 

17.11

 

1063

17.68

1087

 

 

18.25

 

1110

 

18.83

1133

 

19.41

1155

 

19.99

16,000

1028

18.17

 

1051

 

18.76

1074

 

19.34

 

1097

19.93

1120

 

 

20.52

 

1142

 

21.12

1164

 

21.71

1185

 

22.31

17,000

1066

20.58

 

1089

 

21.18

1111

 

21.78

 

1133

22.39

1154

 

 

23.00

 

1175

 

23.61

1197

 

24.23

Ð

 

Ð

18,000

1106

23.19

 

1127

 

23.82

1148

 

24.44

 

1169

25.07

1190

 

 

25.69

 

Ð

 

Ð

 

Ð

 

Ð

Ð

 

Ð

19,000

1146

26.04

 

1166

 

26.68

1187

 

27.32

 

Ð

Ð

Ð

 

Ð

Ð

 

Ð

 

 

Ð

 

Ð

Ð

 

Ð

20,000

1187

29.11

 

Ð

 

 

Ð

 

Ð

 

 

Ð

Ð

Ð

Ð

Ð

 

 

Ð

 

Ð

 

 

 

Ð

 

Ð

Ð

 

Ð

 

 

 

 

 

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

AIRFLOW

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.4

 

 

 

 

 

3.6

 

 

3.6

 

 

Bhp Ð

 

Brake Horsepower

 

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

13,000

1124

 

16.48

 

1148

 

17.03

 

1171

 

17.59

1.

Fan performance is based on wet coils, economizer, roof curb,

14,000

1150

 

18.43

 

1173

 

19.00

 

1195

 

19.57

 

 

cabinet losses, and clean 2-in. ®lters.

 

 

 

15,000

1177

 

20.57

 

1199

 

21.16

 

Ð

 

Ð

2.

Conversion − Bhp to watts:

 

 

 

 

 

 

16,000

Ð

 

Ð

 

 

Ð

 

 

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

Bhp x 746

 

 

 

 

 

 

17,000

Ð

 

Ð

 

 

Ð

 

 

 

Ð

Ð

Ð

 

 

 

 

Watts =

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor efficiency

 

 

 

 

 

 

18,000

Ð

 

Ð

 

 

Ð

 

 

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19,000

Ð

 

Ð

 

 

Ð

 

 

 

Ð

Ð

Ð

 

 

 

3. VAV units will operate down to 70 cfm/ton.

 

 

 

20,000

Ð

 

Ð

 

 

Ð

 

 

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table 15 Ð Air Quantity Limits

UNIT

MINIMUM HEATING

MINIMUM COOLING

MINIMUM COOLING

MAXIMUM

50EJ,EK,EW,EY

CFM

CFM (VAV)

CFM (CV)

CFM

024

6,000

2000

6,000

10,000

028

7,500

2500

7,500

12,500

030

8,250

2750

8,250

13,750

034

9,000

3000

9,000

15,000

038

10,500

3500

10,500

17,500

044

12,000

4000

12,000

20,000

048

13,500

4500

13,500

22,500

 

 

 

 

 

LEGEND

CV Ð Constant Volume

VAV Ð Variable Air Volume

38

Page 38
Image 38
Carrier 50EY, 50EW, 50EK Fan Performance, 50EJ048 Ð Vertical Discharge Units, Air Quantity Limits, Cfm Cv