Carrier 50EK, 50EJ, 50EW, 50EY Start-Upchecklist, Pre-Start-Up, Electrical, Temperatures, Pressures

Models: 50EK 50EY 50EW 50EJ

1 56
Download 56 pages 61.69 Kb
Page 55
Image 55

START-UP CHECKLIST

MODEL NO.:

 

 

SERIAL NO.:

 

 

SOFTWARE VERSION (SEE FIG. 15)

 

 

 

 

TECHNICIAN:

 

DATE:

 

 

 

 

 

 

 

 

 

 

PRE-START-UP:

VERIFY THAT DIP SWITCH SETTINGS ARE CORRECT

VERIFY THAT ALL PACKING MATERIALS HAVE BEEN REMOVED FROM UNIT

REMOVE ALL SHIPPING HOLDDOWN BOLTS AND BRACKETS PER INSTRUCTIONS

VERIFY INSTALLATION OF ECONOMIZER HOOD

VERIFY INSTALLATION OF ALL OPTIONS AND ACCESSORIES

VERIFY THAT CONDENSATE CONNECTION IS INSTALLED PER INSTRUCTIONS

VERIFY THAT ALL ELECTRICAL CONNECTIONS AND TERMINALS ARE TIGHT

CHECK THAT INDOOR-AIR FILTER IS CLEAN AND IN PLACE

VERIFY THAT UNIT IS LEVEL WITHIN TOLERANCES

CHECK FAN WHEELS AND PROPELLERS FOR LOCATION IN HOUSING/ORIFICE, AND VERIFY SET SCREW IS TIGHT

VERIFY THAT FAN SHEAVES ARE ALIGNED AND BELTS ARE PROPERLY TENSIONED

VERIFY THAT SUCTION, DISCHARGE, AND LIQUID LINE SERVICE VALVES ON EACH CIRCUIT ARE OPEN

START-UP

ELECTRICAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SUPPLY VOLTAGE L1-L2

 

 

 

L2-L3

 

 

 

L3-L1

 

 

 

COMPRESSOR AMPS Ð COMPRESSOR NO. 1

L1

 

 

L2

 

 

 

 

 

L3

 

 

Ð COMPRESSOR NO. 2

L1

 

 

L2

 

 

 

 

 

L3

 

 

SUPPLY FAN AMPS (CV)

 

 

 

EXHAUST FAN AMPS

 

 

 

 

 

 

 

 

 

 

 

 

 

(VAV)

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*VAV fan supply amps reading must be taken with a true RMS meter for accurate readings.

 

ELECTRIC HEAT AMPS (IF SO EQUIPPED)

L1

 

 

 

 

L2

 

 

 

 

 

 

 

L3

 

TEMPERATURES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTDOOR-AIR TEMPERATURE

 

 

 

 

F

DB (Dry-Bulb)

 

 

 

 

 

 

 

 

 

 

 

 

 

RETURN-AIR TEMPERATURE

 

 

 

 

F

DB

 

 

F

WB (Wet-Bulb)

 

COOLING SUPPLY AIR

 

 

 

 

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC HEAT SUPPLY AIR (IF SO EQUIPPED)

 

 

 

F

 

 

 

 

PRESSURES

 

 

 

 

 

 

 

 

 

 

 

REFRIGERANT SUCTION

CIRCUIT NO. 1

 

 

 

PSIG

CIRCUIT NO. 2

 

 

 

PSIG

REFRIGERANT DISCHARGE

CIRCUIT NO. 1

 

 

 

PSIG

CIRCUIT NO. 2

 

 

 

PSIG

VERIFY REFRIGERANT CHARGE USING CHARGING CHARTS ON PAGE 45

CL-1

Page 55
Image 55
Carrier 50EK, 50EJ, 50EW, 50EY installation instructions Start-Upchecklist, Pre-Start-Up, Electrical, Temperatures, Pressures