AIRFLOW

Table 12 Ð Fan Performance, 50EJ/EK024-034 Ð Vertical Discharge Units

FOR EW/EY UNITS, REDUCE NET AVAILABLE EXTERNAL STATIC PRESSURE BY 0.3 IN. WG

AIRFLOW

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

0.2

0.4

 

 

 

 

 

0.6

 

 

0.8

 

1.0

 

 

 

1.2

 

 

1.4

 

 

1.6

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

 

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

4,000

322

0.77

401

 

1.09

 

466

 

1.43

 

523

 

1.78

575

 

2.13

 

622

 

2.50

666

 

2.87

 

707

 

3.25

5,000

361

1.14

433

 

1.50

 

494

 

1.86

 

548

 

2.23

598

 

2.62

 

643

 

3.00

686

 

3.40

 

726

 

3.80

6,000

403

1.62

468

 

2.01

 

526

 

2.41

 

577

 

2.81

624

 

3.21

 

668

 

3.62

709

 

4.04

 

748

 

4.46

7,000

448

2.22

508

 

2.65

 

561

 

3.08

 

609

 

3.50

654

 

3.93

 

696

 

4.37

736

 

4.81

 

773

 

5.25

8,000

495

2.97

549

 

3.42

 

599

 

3.88

 

645

 

4.33

687

 

4.79

 

727

 

5.25

765

 

5.71

 

801

 

6.18

8,250

507

3.18

560

 

3.64

 

609

 

4.10

 

654

 

4.56

696

 

5.02

 

735

 

5.49

773

 

5.96

 

809

 

6.43

9,000

543

3.85

593

 

4.34

 

639

 

4.82

 

682

 

5.30

723

 

5.78

 

761

 

6.27

797

 

6.76

 

832

 

7.24

10,000

592

4.90

638

 

5.41

 

682

 

5.91

 

722

 

6.42

760

 

6.93

 

797

 

7.44

832

 

7.95

 

865

 

8.46

11,000

642

6.10

685

 

6.64

 

725

 

7.17

 

764

 

7.70

800

 

8.24

 

835

 

8.77

868

 

9.30

 

900

 

9.84

12,000

693

7.48

733

 

8.04

 

771

 

8.60

 

807

 

9.15

841

 

9.71

 

874

 

10.26

906

 

10.82

 

937

 

11.38

12,500

718

8.23

757

 

8.80

 

794

 

9.37

 

829

 

9.94

862

 

10.51

 

895

 

11.08

926

 

11.64

 

956

 

12.21

13,000

744

9.03

781

 

9.62

 

817

 

10.20

 

851

 

10.78

884

 

11.36

 

915

 

11.93

946

 

12.51

 

975

 

13.09

13,750

783

10.32

818

10.92

 

852

 

11.52

 

885

 

12.12

917

 

12.71

 

947

 

13.31

977

 

13.90

 

1005

 

14.50

14,000

795

10.77

831

11.38

 

864

 

11.98

 

896

 

12.59

928

 

13.19

 

958

 

13.79

987

 

14.39

 

1015

 

14.99

15,000

847

12.71

880

13.34

 

912

 

13.96

 

943

 

14.59

972

 

15.21

 

1001

 

15.83

1029

 

16.45

 

1056

 

17.08

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

1.8

2.0

 

 

 

 

 

2.2

 

 

2.4

 

2.6

 

 

 

2.8

 

 

3.0

 

 

3.2

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

 

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

Rpm

 

Bhp

 

Rpm

 

Bhp

4,000

746

3.64

783

 

4.03

 

818

 

4.44

 

852

 

4.85

884

 

5.26

 

916

 

5.68

946

 

6.11

 

975

 

6.54

5,000

764

4.21

800

 

4.62

 

834

 

5.04

 

868

 

5.46

900

 

5.89

 

930

 

6.33

960

 

6.77

 

989

 

7.22

6,000

785

4.89

820

 

5.32

 

854

 

5.76

 

886

 

6.21

918

 

6.65

 

948

 

7.11

977

 

7.56

 

1006

 

8.02

7,000

809

5.70

843

 

6.16

 

876

 

6.61

 

908

 

7.08

939

 

7.54

 

968

 

8.01

997

 

8.49

 

1025

 

8.96

8,000

836

6.65

869

 

7.12

 

901

 

7.60

 

932

 

8.08

962

 

8.57

 

991

 

9.05

1019

 

9.55

 

1046

 

10.04

8,250

843

6.91

876

 

7.39

 

908

 

7.87

 

938

 

8.36

968

 

8.84

 

997

 

9.34

1025

 

9.83

 

1052

 

10.33

9,000

865

7.74

898

 

8.23

 

929

 

8.73

 

959

 

9.23

988

 

9.74

 

1016

 

10.24

1043

 

10.75

 

1070

 

11.27

10,000

897

8.98

928

 

9.49

 

958

 

10.01

 

987

 

10.53

1016

 

11.06

 

1043

 

11.58

1070

 

12.11

 

1096

 

12.64

11,000

931

10.37

961

10.91

 

990

 

11.45

 

1018

 

11.99

1046

 

12.54

 

1073

 

13.08

1099

 

13.63

 

1124

 

14.18

12,000

967

11.94

996

12.49

 

1024

 

13.06

 

1051

 

13.62

1078

 

14.18

 

1104

 

14.75

1129

 

15.31

 

1154

 

15.88

12,500

985

12.78

1014

13.35

 

1041

 

13.92

 

1068

 

14.49

1094

 

15.07

 

1120

 

15.64

1145

 

16.22

 

1169

 

16.80

13,000

1004

13.67

1032

14.25

 

1059

 

14.83

 

1086

 

15.42

1111

 

16.00

 

1137

 

16.59

1161

 

17.17

 

1185

 

17.76

13,750

1033

15.09

1060

15.69

 

1087

 

16.29

 

1112

 

16.88

1138

 

17.48

 

1162

 

18.08

1186

 

18.68

 

Ð

 

Ð

14,000

1043

15.59

1070

16.19

 

1096

 

16.79

 

1122

 

17.40

1147

 

18.00

 

1171

 

18.60

1195

 

19.21

 

Ð

 

Ð

15,000

1083

17.70

1109

18.32

 

1134

 

18.94

 

1159

 

19.56

1183

 

20.19

 

Ð

 

Ð

Ð

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW

AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3.4

 

 

 

3.6

 

 

 

3.8

 

 

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

(Cfm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

Rpm

 

Bhp

 

 

Bhp Ð Brake Horsepower

 

 

 

 

 

 

 

4,000

1004

 

6.97

 

1032

 

 

7.41

 

1059

 

7.86

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

5,000

1017

 

7.67

 

1045

 

 

8.12

 

1072

 

8.58

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Fan performance is based on wet coils, economizer, roof curb,

6,000

1034

 

8.49

 

1061

 

 

8.96

 

1087

 

9.43

 

 

 

 

 

 

 

 

 

 

 

cabinet losses, and clean 2-in. ®lters.

 

 

 

 

7,000

1052

 

9.44

 

1079

 

 

9.93

 

1105

 

10.42

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2. Conversion Ð Bhp to watts:

 

 

 

 

 

 

 

8,000

1073

 

10.54

 

1099

 

11.04

 

1125

 

11.55

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bhp x 746

 

 

 

 

 

 

 

8,250

1079

 

10.84

 

1105

 

11.34

 

1130

 

11.85

 

 

 

Watts =

 

 

 

 

 

 

 

9,000

1096

 

11.78

 

1122

 

12.30

 

1147

 

12.82

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Motor efficiency

 

 

 

 

 

 

 

10,000

1122

 

13.18

 

1147

 

13.71

 

1171

 

14.25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. VAV units will operate down to 70 cfm/ton.

 

 

 

 

11,000

1149

 

14.73

 

1173

 

15.29

 

1197

 

15.84

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12,000

1178

 

16.45

 

1202

 

17.03

 

Ð

 

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12,500

1193

 

17.38

 

Ð

 

 

Ð

 

 

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13,000

Ð

 

Ð

 

Ð

 

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13,750

Ð

 

Ð

 

Ð

 

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14,000

Ð

 

Ð

 

Ð

 

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15,000

Ð

 

Ð

 

Ð

 

 

Ð

Ð

Ð

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 