Table 1 Ð Physical Data (cont)

UNIT 50EJ,EK,EW,EY

 

038

 

 

 

044

 

 

 

 

048

 

 

NOMINAL CAPACITY (tons)

 

35

 

 

 

40

 

 

 

 

45

 

 

OPERATING WEIGHT (lb)*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Al/Al²

 

4282

 

 

 

4508

 

 

 

 

4795

 

 

Al/Cu²

 

4567

 

 

 

4793

 

 

 

 

5175

 

 

Roof Curb (14-in. curb)

 

410

 

 

 

410

 

 

 

 

410

 

 

COMPRESSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type Ckt 1

 

06D537

 

 

 

06EA250

 

 

 

06EA265

 

 

Ckt 2

 

06D537

 

 

 

06EA250

 

 

 

06EA250

 

 

Number of Refrigerant Circuits

 

2

 

 

 

2

 

 

 

 

2

 

 

Oil (oz) (Ckt1, Ckt 2)

 

115 ea.

 

 

 

224 ea.

 

 

 

304, 224

 

 

REFRIGERANT TYPE

 

 

 

 

 

R-22

 

 

 

 

 

 

 

Operating Charge (lb-oz)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit 1**

 

34-0

 

 

 

35-0

 

 

 

 

41-0

 

 

Circuit 2

 

34-0

 

 

 

35-0

 

 

 

 

41-0

 

 

CONDENSER COIL

 

 

 

Cross-Hatched 3¤8 Copper Tubes, Aluminum Lanced or Copper Fins

 

 

 

 

Quantity

 

2

 

 

 

2

 

 

1

 

 

 

1

Rows...Fins/in.

 

3...15

 

 

 

3...15

 

 

4...15

 

 

3...15

Total Face Area (sq ft)

 

58.3

 

 

 

58.3

 

 

 

 

66.7

 

 

CONDENSER FAN

 

 

 

 

 

Propeller Type

 

 

 

 

 

 

 

Nominal Cfm

 

27,064

 

 

 

27,064

 

 

 

 

27,064

 

 

Quantity...Diameter (in.)

 

4...30

 

 

 

4...30

 

 

 

 

4...30

 

 

Motor Hp (1075 Rpm)

 

1

 

 

 

1

 

 

 

 

1

 

 

EVAPORATOR COIL

 

 

Cross-Hatched 3¤8 Copper Tubes, Aluminum or Copper Plate Fins, Intertwined Circuits

 

 

Rows...Fins/in.

 

3...15

 

 

 

3...15

 

 

 

 

4...15

 

 

Total Face Area (sq ft)

 

34.7

 

 

 

34.7

 

 

 

 

34.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EVAPORATOR FAN

 

 

 

 

 

Centrifugal Type

 

 

 

 

 

 

 

Quantity...Size (in.)

 

2..20x15

 

 

 

2...20x15

 

 

 

2...20x15

 

 

Type Drive

 

Belt

 

 

 

Belt

 

 

 

Belt

 

 

Nominal Cfm

 

14,000

 

 

 

16,000

 

 

 

 

18,000

 

 

Motor Hp

10

15²²

 

20

15

20²²

 

25

20

 

25²²

 

 

30

Motor Frame Size

S215T

S254T

 

S256T

S254T

S256T

 

S284T

S256T

 

S284T

 

S286T

Motor Bearing Type

 

Ball

 

 

 

Ball

 

 

 

 

Ball

 

 

Maximum Allowable Rpm

 

1200

 

 

 

1200

 

 

 

 

1200

 

 

Motor Pulley Pitch Diameter

4.1

6.9

 

7.5

6.9

8.1

 

9.1

5.3

 

5.9

 

7.5

Nominal Motor Shaft Diameter (in.)

13¤8

15¤8

 

15¤8

15¤8

15¤8

 

11¤8

15¤8

 

17¤8

 

17¤8

Fan Pulley Pitch Diameter (in.)

9.1

12.5

 

12.5

12.5

13.7

 

13.7

9.1

 

9.1

 

11.1

Nominal Fan Shaft Diameter (in.)

 

111¤16

 

 

 

111¤16

 

 

 

 

111¤16

 

 

Belt, Quantity...Type

1...BX51

1...5VX630

 

1...5VX650

1...5VX630

1...5VX670

 

2...5VX680

1...5VX550

 

2...5VX560

 

2...5VX610

Belt, Length (in.)

54

63

 

65

63

67

 

68

55

 

56

 

59

Pulley Center Line Distance (in.)

15.6-18.4

15.0-17.9

15.0-17.9

 

14.6-17.6

15.0-17.9

 

14.6-17.6

 

14.6-17.6

Factory Speed Setting (rpm)

788

966

 

1050

1066

1035

 

1162

1019

 

1135

 

1182

HIGH-PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cutout

 

426

 

 

 

426

 

 

 

 

426

 

 

Reset (Auto.)

 

320

 

 

 

320

 

 

 

 

320

 

 

LOW-PRESSURE SWITCH (psig)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cutout

 

7

 

 

 

7

 

 

 

 

7

 

 

Reset (Auto.)

 

22

 

 

 

22

 

 

 

 

22

 

 

RETURN-AIR FILTERS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Quantity...Size (in.)

 

10...20x24x2

 

10...20x24x2

 

 

 

10..20x24x2

 

 

OUTDOOR-AIR FILTERS

 

8...16x25

 

 

 

8...16x25

 

 

 

8...16x25

 

 

Quantity...Size (in.)

 

4...20x25

 

 

 

4...20x25

 

 

 

4...20x25

 

 

POWER EXHAUST

 

Direct Drive, 3-Speed, Single-Phase Motor (Factory-Wired For High Speed) and Forward Curved Fan

 

 

Motor, Quantity...Hp

 

 

 

 

 

4...1

 

 

 

 

 

 

 

 

Fan, Diameter...Width (in.)

 

 

 

 

 

11...10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

Al Ð Aluminum

Cu Ð Copper

*Weight of unit does not include variable frequency drive (VFD), barometric relief, or power exhaust. If a VAV unit (a VFD is installed), add the VFD weight in the table at right.

²Evaporator coil ®n material/condenser coil ®n material.

**Sizes 024-034: Circuit 1 uses the lower portion of condenser coil, Circuit 2 uses the upper portion. Sizes 038-048: Circuit 1 uses the left condenser coil, Circuit 2 the right. All units have intertwined evaporator coils.

²²Motor and drive shown will deliver approximately 2.5 in. wg net external static. For more drive information, see Table 2.

NOTES:

1.See Table 2 for optional evaporator fan motor data.

2.Sizes 038 and 048 are 50EJ,EW units only.

VFD

 

VFD WEIGHTS (lb)

 

(Hp)

208/230 v

 

460 v

575 v

5

20

 

22

60

7.5

51

 

37

64

10

51

 

61

64

15

61

 

63

109

20

63

 

111

109

25

105

 

112

174

30

172

 

118

180

 

 

 

 

 

10