Table 5C Ð Superheat Charging Table, 50SS030

TEMP (F)

 

 

 

 

 

 

EVAP AIR Ð CFM

 

 

 

 

 

 

 

 

 

 

 

 

1000

 

 

 

 

 

 

AIR ENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap Air Ð Ewb (F)

 

 

 

 

 

 

COND

 

 

 

 

 

 

 

 

 

 

 

 

 

54

56

58

60

62

 

64

 

66

 

68

70

72

74

76

65

 

SPH

14.2

15.1

16.1

17.1

19.2

 

21.3

 

23.3

 

24.7

25.9

27.2

27.8

28.5

70

 

SPH

13.6

14.1

14.6

15.0

17.1

 

19.2

 

21.3

 

22.8

24.2

25.7

26.3

26.9

75

 

SPH

13.0

13.0

13.0

13.0

15.1

 

17.2

 

19.2

 

20.9

22.6

24.2

24.8

25.4

80

 

SPH

10.9

11.0

11.0

10.9

13.6

 

16.1

 

18.7

 

20.1

21.4

22.7

23.6

24.4

85

 

SPH

8.9

8.9

8.9

8.9

12.0

 

15.1

 

18.2

 

19.2

20.2

21.2

22.4

23.5

90

 

SPH

8.3

8.4

8.4

8.3

10.9

 

13.6

 

16.2

 

17.7

19.2

20.8

21.6

22.5

95

 

SPH

7.8

7.8

7.8

7.8

9.9

 

12.0

 

14.1

 

16.1

18.2

20.2

20.9

21.7

100

 

SPH

7.3

7.3

7.3

7.3

9.3

 

11.4

 

13.6

 

15.6

17.6

19.7

20.2

20.7

105

 

SPH

6.7

6.7

6.7

6.7

8.8

 

10.9

 

13.0

 

15.0

17.1

19.1

19.4

19.8

110

 

SPH

*

*

*

*

6.7

 

8.9

 

10.9

 

13.0

15.0

17.1

18.0

18.9

115

 

SPH

*

*

*

*

*

 

6.8

 

8.9

 

10.9

13.0

15.0

16.5

18.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

*Do not attempt to charge system under these conditions Ð refrigerant slugging may occur.

Ewb Ð Entering Wet Bulb

 

SPH Ð Superheat at Compressor (F)

 

Table 5D Ð Superheat Charging Table, 50SS036

TEMP (F)

 

 

 

 

 

EVAP AIR Ð CFM

 

 

 

 

 

 

 

 

 

 

 

1200

 

 

 

 

 

 

AIR ENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap Air Ð Ewb (F)

 

 

 

 

 

 

COND

 

 

 

 

 

 

 

 

 

 

 

 

 

54

56

58

60

62

64

66

 

68

70

72

74

76

65

 

SPH

8.4

8.4

8.4

8.4

12.5

16.7

18.7

 

20.7

22.0

23.4

24.8

26.1

70

 

SPH

5.0

5.0

5.0

5.0

9.0

13.1

15.9

 

18.6

20.0

21.3

22.7

24.0

75

 

SPH

*

*

*

*

5.4

9.6

13.1

 

16.6

17.9

19.3

20.6

22.0

80

 

SPH

*

*

*

*

*

6.0

10.3

 

14.5

15.9

17.3

18.6

20.0

85

 

SPH

*

*

*

*

*

*

7.5

 

12.5

13.9

15.2

16.5

17.9

90

 

SPH

*

*

*

*

*

*

5.4

 

10.4

12.5

14.6

16.8

18.8

95

 

SPH

*

*

*

*

*

*

*

 

8.4

11.3

14.1

17.0

19.8

100

 

SPH

*

*

*

*

*

*

*

 

6.4

10.0

13.5

17.1

20.7

105

 

SPH

*

*

*

*

*

*

*

 

*

8.7

13.0

17.3

21.7

110

 

SPH

*

*

*

*

*

*

*

 

*

9.3

12.4

15.6

18.7

115

 

SPH

*

*

*

*

*

*

*

 

*

10.0

11.9

13.8

15.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

*Do not attempt to charge system under these conditions Ð refrigerant slugging may occur.

Ewb Ð Entering Wet Bulb

 

SPH Ð Superheat at Compressor (F)

 

Table 5E Ð Superheat Charging Table, 50SS042

TEMP (F)

 

 

 

 

 

EVAP AIR Ð CFM

 

 

 

 

 

 

 

 

 

 

 

1400

 

 

 

 

 

 

AIR ENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Evap Air Ð Ewb (F)

 

 

 

 

 

 

COND

 

 

 

 

 

 

 

 

 

 

 

 

 

54

56

58

60

62

64

 

66

 

68

70

72

74

76

65

 

SPH

11.0

11.0

11.0

14.0

17.0

20.0

 

22.0

 

24.0

26.0

26.0

27.7

28.6

70

 

SPH

7.5

7.5

7.5

10.4

13.4

16.4

 

18.9

 

21.4

24.0

25.0

26.1

27.1

75

 

SPH

*

*

*

6.9

9.9

12.9

 

15.9

 

18.9

21.9

23.2

24.4

25.7

80

 

SPH

*

*

*

5.9

8.4

10.8

 

13.8

 

16.8

19.8

21.3

22.8

24.3

85

 

SPH

*

*

*

5.0

6.9

8.8

 

11.8

 

14.8

17.8

19.5

21.1

22.8

90

 

SPH

*

*

*

*

6.0

6.8

 

10.2

 

13.7

17.3

18.6

20.0

21.4

95

 

SPH

*

*

*

*

*

5.0

 

8.7

 

12.7

16.7

17.8

18.9

20.0

100

 

SPH

*

*

*

*

*

*

 

6.5

 

10.5

14.6

16.4

18.2

20.0

105

 

SPH

*

*

*

*

*

*

 

*

 

8.4

12.6

15.1

17.6

20.0

110

 

SPH

*

*

*

*

*

*

 

*

 

8.0

12.0

14.2

16.4

18.6

115

 

SPH

*

*

*

*

*

*

 

*

 

7.7

11.5

13.4

15.3

17.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LEGEND

Ewb Ð Entering Wet Bulb

SPH Ð Superheat at Compressor (F)

29

Page 29
Image 29
Carrier 50SS018-060, 50SX024-060 Ð Superheat Charging Table, 50SS030, Ð Superheat Charging Table, 50SS036, 1000, 1400