Figure 21 Alarm Indicator Terminal Block Connections

ALARMS 50VA SELV max

NC

COM MINOR

NO

NC

COM MAJOR

NO

NC

COM CRITICAL

NO

32694

Step 4 Connect one set of alarm indicator wires to the alarm terminal block as follows:

a.Connect one lead to the common (COM) terminal.

b.Connect the other lead to the normally closed (NC) or normally open (NO) terminal.

Caution Figure 21 shows the wiring configuration for normally open (NO) alarm relays. If you are wiring the router in series with other equipment for the alarm indicators, use the normally closed (NC) terminals. If you are wiring the router in parallel with other equipment for the alarm indicators, use the NO terminals.

Step 5 Repeat Step 3 and Step 4 for any remaining alarm indicators.

28

Page 28
Image 28
Cisco Systems 10008 quick start Alarm Indicator Terminal Block Connections