Appendix A Command Reference
rpr-ieee flag c2 value
rpr-ieee flag c2 value
Use this command to specify the SONET C2 byte path overhead values for both
IEEE 802.17b based RPR spans.
Syntax Description
Defaults The default is 0x1B, which indicates GFP encapsulation.
Command Modes IEEE 802.17b based RPR interface configuration
Usage Guidelines This value would only be changed if you do not want to specify GFP encapsulation for the span. In
practical terms, ths term would almost never be changed.
Examples In this example, interface is shortened to int.
Router(config)# int rpr-ieee 0
Router(config-if)# rpr-ieee flag c2 0
Related Commands None
Parameter Description
value The bytes that the path signal uses to flag the IEEE 802.17b based RPR
interface for faults. The numeric value range is 0 to 255, and the de fault is
0 (0x1b) for generic framing procedure (GFP) encapsulation.