A-78
Ethernet Card Software Feature and Configuration Guide, R7.2
January 2009
Appendix A Command Reference
[no] shutdown
[no] shutdown
Use this command to place a POS or IEEE 802.17b based RPR in terface in pass-through mode. This
command has no arguments or keywords. Use the no form of this command to reverse the shutdown.
Defaults The default is not shut down.
Command Modes POS or IEEE 802.17b based RPR interface configuration
Usage Guidelines For GFP and high-level data link control (HDLC) modes, the POS shutdown causes a path alarm
indication signal (AIS-P) to be sent to the peer. In RPR-IEEE mode, AIS-P is not inserted toward the
peer.
In this command, shutdown can be shortened to shut.
Examples In this example, interface is shortened to int.
Router(config)# int pos 0
Router(config-if)# shut
Related Commands None