Chapter 5 Parameters and Defaults

Optional Feature Parameters

0>#t811.rat4—If the first digit entered is 0, the timeout before automatic send is eight seconds, and the terminating character # can be entered at any time to manually send the dial string. If the first three digits entered are 011, then, after an additional 11 digits are entered, the timeout before an automatic send changes to four seconds. The user can enter more digits until the dial string is sent by the timeout or by the user entering the # character.

^1t4>#.—If the first digit entered is anything other than 1, the timeout before an automatic send is four seconds. The terminating character # can be entered at any time to manually send the dial string. The user can enter more digits until the dial string is sent by the timeout or by the user entering the

# character.

Dial Plan Example 2

The following dial plans:

.t7>#

t4-9111t7>#

t1-0t4>#.t7-

or

.t7>#r6t4-9111t7>#.r9t1-0t4>#.t7-

consist of the following rules:

.t7>#r6t4-—You must enter at least one digit. After the first digit is entered and matched by the dial plan, the timeout before an automatic send is seven seconds, and the terminating character # can be entered at any time to manually send the dial string. After seven digits are entered, the timeout before an automatic send changes to two seconds. The - symbol at the end of the rule allows further digits to be entered until the dial string is sent by the timeout or the user entering the # character.

911—If the dial string 911 is entered, send this string immediately.

1t7>#.r9t1—If the first digit entered is 1, the timeout before an automatic send is seven seconds, and the terminating character # can be entered at any time to manually send the dial string. After the 11th digit is entered, the timeout before an automatic send changes to one second. The user can enter more digits until the dial string is sent by the timeout or by the user entering the # character.

0t4>#.t7—If the first digit entered is 0, the timeout before an automatic send is four seconds, and the terminating character # can be entered at any time to manually send the dial string. After the second digit is entered, the timeout before an automatic send changes to seven seconds. The user can enter more digits until the dial string is sent by the timeout or by the user entering the # character.

Dial Plan Blocking (In Rule)

Dial plan blocking can be used to reduce the occurrences of invalid dialed digits being sent and can prevent the dialed string of a specified pattern from being sent. By adding dial plan blocking, dialed digits are discarded after the interdigit timer expires unless one of the specified matching rules is met.

In addition, the default nine-second global interdigit timeout value is also modified with the value specified in the dial plan blocking command:

In

where n specifies the global interdigit timeout and the valid values are 1-9 and a-z (10-35).

Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator’s Guide (H.323)

 

OL-4008-01

5-39

 

 

 

Page 109
Image 109
Cisco Systems ATA 188 manual Dial Plan Blocking In Rule, Following dial plans

ATA 188 specifications

The Cisco Systems ATA 188 is a versatile Analog Telephone Adapter designed to facilitate the integration of traditional telephone systems with Voice over Internet Protocol (VoIP) networks. This device has been key in bridging the gap between legacy telephony and modern IP-based communication, allowing users to leverage their existing analog phones while enjoying the benefits of digital connectivity.

One of the main features of the ATA 188 is its ability to connect regular analog phones to a VoIP network, enabling users to make and receive calls over the internet. This significantly reduces calling costs, especially for long-distance and international calls. The ATA 188 supports two phone lines, allowing simultaneous voice calls. This dual-line capability makes it a suitable choice for small businesses or home offices that require multiple lines without the need for extensive infrastructure.

The device is equipped with various technologies that enhance its functionality. It supports the Session Initiation Protocol (SIP) and H.323, making it compatible with a wide range of VoIP service providers. Additionally, the ATA 188 features Quality of Service (QoS) settings, which prioritize voice traffic over the internet, ensuring clear voice quality without interruptions or delays. This is essential for maintaining a professional communication experience, especially in business environments.

Another characteristic of the ATA 188 is its user-friendly configuration interface. It allows users to easily set up and manage their devices through a web-based portal. The configuration process is straightforward, with options to adjust settings such as codec selection, call features including call waiting, and call forwarding functionalities.

Security is also a priority for the ATA 188, as it provides robust protocols to protect call data. The device supports Secure Real-time Transport Protocol (SRTP) and Transport Layer Security (TLS) to encrypt voice traffic and manage signaling securely. This ensures that sensitive conversations remain confidential.

Overall, the Cisco Systems ATA 188 is a reliable and efficient solution for users looking to transition from traditional telephony to VoIP. Its dual-line capacity, compatibility with multiple VoIP standards, user-friendly configuration, and built-in security features make it a valuable asset for both personal and professional communication solutions. In an ever-evolving telecommunications landscape, the ATA 188 remains a relevant and practical choice for integrating legacy telephony with modern internet-based services.