Cisco Systems IPS4510K9, IPS4520K9 specifications Troubleshooting Loose Connections, 7-34

Models: IPS4510K9

1 36
Download 36 pages 45.7 Kb
Page 34
Image 34
Troubleshooting Loose Connections

Chapter 7 Installing the IPS 4510 and IPS 4520

Troubleshooting Loose Connections

Figure 7-18 Cable Management Brackets for the Slide Rail

333053

Step 4 Tighten the screws in to the rack.

Step 5 Reattach the power cable to the sensor.

Step 6 Organize the cables through the cable management brackets on the sensor.

Step 7 Power on the sensor.

Troubleshooting Loose Connections

Perform the following actions to troubleshoot loose connections on sensors:

Make sure all power cords are securely connected.

Make sure all cables are properly aligned and securely connected for all external and internal components.

Remove and check all data and power cables for damage. Make sure no cables have bent pins or damaged connectors.

Make sure each device is properly seated.

If a device has latches, make sure they are completely closed and locked.

Check any interlock or interconnect indicators that indicate a component is not connected properly.

If problems continue, remove and reinstall each device, checking the connectors and sockets for bent pins or other damage.

 

Cisco Intrusion Prevention System Appliance and Module Installation Guide for IPS 7.1

7-34

OL-24002-01

Page 34
Image 34
Cisco Systems IPS4510K9, IPS4520K9 specifications Troubleshooting Loose Connections, 7-34