Cisco Systems OL-16447-01 manual 3-15, 21 Inserting the Terminal Block in the Block Header

Models: OL-16447-01

1 102
Download 102 pages 41.83 Kb
Page 67
Image 67
Figure 3-21 Inserting the Terminal Block in the Block Header

Chapter 3 Installing and Removing AC- and DC-Power-Supply Modules

Power-Supply Module Installation

Figure 3-20 Completed Wiring of Terminal Block Plug for Telecom Applications

1

2

3

4

280945

1

Return (positive) Feed A

3

Return (positive) Feed B

 

 

 

 

2

Supply (negative) Feed A

4

Supply (negative) Feed B

 

 

 

 

Step 8 Insert the terminal block plug in the terminal block header on the switch front panel. (See Figure 3-21).

Caution Secure the wires coming in from the terminal block so that they cannot be disturbed by casual contact. For example, use tie wraps to secure the wires to the rack.

Figure 3-21 Inserting the Terminal Block in the Block Header

280946

Step 9 Secure the terminal block by using the screws on the far left and right of the terminal block.

Step 10 Remove the tape from the circuit-breaker switch handle, and move the circuit-breaker handle to the ON position.

Step 11 Move the DC-power source circuit-breaker handles to the ON position.

 

 

Cisco ME 3400E Ethernet Access Switch Hardware Installation Guide

 

 

 

 

 

 

OL-16447-01

 

 

3-15

 

 

 

 

 

Page 67