Cisco Systems ONS 15310-MA, ONS 15310-CL manual Assigns the POS interface to the SPR interface

Models: ONS 15310-CL ONS 15310-MA Cisco ONS 15310-MA

1 292
Download 292 pages 38.32 Kb
Page 265
Image 265

Appendix A Command Reference for the ML-Series Card

spr-intf-id shared-packet-ring-number

spr-intf-idshared-packet-ring-number

Assigns the POS interface to the SPR interface.

Syntax Description

Defaults

Command Modes

Usage Guidelines

Examples

Related Commands

ParameterDescription

shared-packet-ring-numberThe only valid shared-packet-ring-number (SPR number) is 1.

N/A

POS interface configuration

The SPR number must be 1, which is the same SPR number assigned to the SPR interface.

The members of the SPR interface must be POS interfaces.

An SPR interface is configured similarly to a EtherChannel (port-channel) interface. Instead of using the channel-groupcommand to define the members, you use the spr-intf-IDcommand. Like port-channel, you then configure the SPR interfaces instead of the POS interface.

The following example assigns an ML-Series card POS interface to an SPR interface with a shared-packet-ring-number of 1:

ML_Series(config)# interface pos 0

ML_Series(config-if)# spr-intf-id 1

interface spr 1

spr station-id

spr wrap

Cisco ONS 15310-CL, ONS 15310-MA, and ONS 15310-MA SDH Ethernet Card Software Feature and Configuration Guide, R9.1 and R9.2

 

78-19415-01

A-21

 

Page 265
Image 265
Cisco Systems ONS 15310-MA manual Assigns the POS interface to the SPR interface, Interface spr Spr station-id Spr wrap